Function List (Extended Function Parameters) - Mitsubishi Electric FR-V520-1.5K to 55K Instruction Manual

Vector inverter
Hide thumbs Also See for FR-V520-1.5K to 55K:
Table of Contents

Advertisement

5.2 Function list (Extended function parameters)

Refer to page 50 for the function list of simple mode parameters.
The extended function parameters are made valid by setting "1" in Pr. 160 "extended function selection".
(
Refer to page 28 for the setting method, and to the Instruction Manual (detailed) for details.)
Name
Torque boost
Made valid for V/F control.
0
(manual)
0 to 30%
1
Maximum speed
0 to 3600r/min
2
Minimum speed
0 to 3600r/min
Made valid for V/F control.
3
Base frequency
20 to 200Hz
Multi-speed setting
4
0 to 3600r/min
(high speed)
Multi-speed setting
5
0 to 3600r/min
(middle speed)
Multi-speed setting
6
0 to 3600r/min
(low speed)
7
Acceleration time
0 to 3600s/ 0 to 360s
8
Deceleration time
0 to 3600s/ 0 to 360s
Electronic thermal O/
9
0 to 3600s/ 0 to 360s
L relay
DC injection brake
10
operation speed
Set the stopping accuracy of positioning operation or the like according to the load by
DC injection brake
adjusting the speed (0 to 1500r/min, 9999), time (0 to 0.5s) and voltage (0 to 30%) that
11
operation time
are used to operate the braking torque at a motor stop for V/F control. (For vector
control, these functions follow pre-excitation selection at not more than the speed in Pr.
DC injection brake
10.)
12
voltage
Set the speed at a start.
13 Starting speed
0 to 1500r/min
15 Jog speed setting
Speed command (0 to 1500r/min) and acceleration/deceleration inclination (0 to 3600s/
Jog acceleration/
0 to 360s) for jog operation.
16
deceleration time
17 MRS input selection
0: Turning MRS on stops output, 2: Turning MRS off stops output
Made valid for V/F control. Represents the magnitude of the output voltage at the base
frequency (Pr. 3).
Base frequency
19
8888: 95% of power supply voltage
voltage
9999: Same as power supply voltage
0 to 1000V, 8888, 9999
Acceleration/
Represents the speed to be referenced to increase or decrease the speed from or to 0r/
20
deceleration
min in the time preset as the acceleration (Pr. 7) or deceleration time (Pr. 8).
reference speed
1 to 3600r/min
Acceleration/
21
deceleration time
0: 0.1s increments, 1: 0.01s increments
increments
Torque restriction
You can set the level of torque restriction.
22
level
0 to 400%
By setting a value other than "9999", set speeds 4 to 7.
Multi-speed setting
24
ON/OFF of the contact signals (RH, RM, RL signals) are combined to change the
(speed 4)
running speed in stages.
Multi-speed setting
25
(speed 5)
Multi-speed setting
26
(speed 6)
Multi-speed setting
27
(speed 7)
0 to 3600r/min, 9999
The multiple speeds can be increased or overridden for compensation.
Multi-speed input
28
0: Without compensation
compensation
1: With compensation
Outline
RH
RM
RL
Speed 4
OFF
ON
ON
Speed 5
ON
OFF
ON
Speed 6
ON
ON
OFF
Speed 7
ON
ON
ON
54
Function list (Extended function
At-a-glance Guide to Func-
" " " " : Usable function
×: Unusable function
Cus-
* : Functions that can be used
Factory
tomer
for param eter-set position con-
Setting
Set-
ting
Speed
control
4% /3% /2%
(3.7K or
×
less/5.5K ,
7.5K/11K
or m ore)
" " " "
1500r/m in
" " " "
0r/m in
×
50Hz
" " " "
1500r/m in
" " " "
750r/m in
" " " "
150r/m in
5s/15s
1.5 K to
" " " "
5.5K / 7.5K
to 55K
5s/15s
1.5 K to
" " " "
5.5K / 7.5K
to 55K
5s/15s
1.5 K to
" " " "
5.5K / 7.5K
to 55K
" " " "
15r/min
" " " "
0.5s
4%/2%
(7.5K or
×
less/11K
or more)
" " " "
15r/min
" " " "
150r/min
" " " "
0.5s
" " " "
0
×
9999
1500r/
" " " "
min
" " " "
0
" " " "
150%
" " " "
9999
" " " "
9999
" " " "
9999
" " " "
9999
" " " "
0
parameters)
tions
trol
Vector Control
Torque
Position
control
control
×
×
" " " "
" " " "
" " " "
×
×
×
" " " "
×*
" " " "
×*
" " " "
×*
" " " "
×*
" " " "
×*
" " " "
" " " "
" " " "
×
" " " "
×
×
×
" " " "
×
" " " "
×
" " " "
×
" " " "
" " " "
×
×
" " " "
×
*
" " " "
×
*
5
×
" " " "
" " " "
×
*
" " " "
×
*
" " " "
×
*
" " " "
×
*
" " " "
×

Advertisement

Table of Contents
loading

Table of Contents