Outline - Mitsubishi Electric FR-V520-1.5K to 55K Instruction Manual

Vector inverter
Hide thumbs Also See for FR-V520-1.5K to 55K:
Table of Contents

Advertisement

1 OUTLINE

<Abbreviations>
• DU: Operation panel (FR-DU04
• PU: Operation panel (FR-DU04
• Inverter: Mitsubishi vector inverter FR-V500 series
• FR-V500: Mitsubishi vector inverter FR-V500 series
• Pr.: Parameter number
• PU operation: Operation using the PU (FR-DU04
• External operation: Operation using the control circuit signals
• Combined operation: Operation using both the PU (FR-DU04
• Dedicated motor: SF-V5R
• Standard motor (with PLG): SF-JR
• Constant-torque motor (with PLG): SF-HRCA
Harmonic Suppression Guideline
The "harmonic suppression guideline for household appliances and general-purpose products" was issued by the
Ministry of Economy, Trade and Industry (formerly Ministry of International Trade and Industry) in September, 1994.
This guideline applies to the 3.7K or less. By installing the power factor improving reactor (FR-BEL or FR-BAL), this
product conforms to the "harmonic suppression technique for transistorized inverters (input current 20A or less)" set
forth by the Japan Electrical Manufactures' Association.
For the 3.7K or more, refer to the Instruction Manual (detailed).
Product check and name of parts
Unpack the inverter and check the capacity plate on the front cover and the rating plate on the inverter side face to
ensure that the product agrees with your order, an accessory L shaped jumper (Refer to page 15 for connection
method.)is included, and the inverter is intact.
nverter type
FR - V520 -
Symbol
Voltage class
Three-phase 200V class
V520
V540
Three-phase 400V class
o. 5 terminal dedicated Lshaped jumper × 1 (supplied)
(1) Front view
POWER lamp
ALARM lamp
.
Capacity plate
*The 5.5K or less inverter is equipped with a built-in brake resistor and the 15K or less inverter is equipped
with a built-in brake transistor.
)
-1
) and parameter unit (FR-PU04V)
-1
Plates
.
K
1.5
Inverter
capacity
(kW)
Operation panel (FR-DU04
)
-1
Brake resistor* (Fitted to the back)
Accessory cover
Wiring port cover for option
Front cover
Rating plate
/FR-PU04V)
-1
/FR-PU04V) and external operation
-1
Rating plate
Inverter type
Input rating
Output rating
Serial number
Capacity plate
Inverter type
(2)
Without front cover
1
Serial number
PU Connector
(Provided with modular jack
type relay connector)
(For use with RS-485 cable
communication)
Modular jack type relay
connector compartment
Inboard option mounting positions
Control circuit terminal block
Main circuit terminal block
Wiring cover

Advertisement

Table of Contents
loading