Placing out of operation

90
Installation and operating manual: PLATINUM inverter H
Version 01/2012
Mat. No. 753 840-AA
12
Placing out of operation

12.1 Dismounting

Danger to life do to DC and AC high voltage!
Â
Wear insulating protective clothing and face
protection.
Â
Have inverters uninstalled by qualified specialists
Danger
only.
The qualified specialist personnel require a license
from the relevant energy suppliers.
Â
Switch off the main power supply (fuse).
Â
Deactivate AC circuit breaker.
Â
Set DC circuit breaker to 0.
Â
Disconnect connections.
Â
Condensers require up to 60 min to discharge.
Do not touch connectors (DC/AC) for at least
5 min after switching off.
Â
Ensure that the DC cables are de-energised.
It is possible that DC cables carry dangerously high
voltages even if the DC switch is deactivated.
When mounting/dismounting in France:
Â
Use special tools for removing the connections.
In case of a PLATINUM inverter without DC switch:
Â
Disconnect in the following order:
1. Remove cable from terminal strip on AC side.
2. Pull DC plug.
Danger to life due to inverter dropping from the wall!
Â
Wear protective shoes.
Â
Ensure a stable position.