Platinum 2100 H Installation And Operating Manual page 32

Hide thumbs Also See for 2100 H:
Table of Contents

Advertisement

PLATINUM inverter H
Connection of the inverter
positive-earthed PV
string
32
Installation and operating manual: PLATINUM inverter H
Version 01/2012
Mat. No. 753 840-AA
With a positive-earthed PV string, connect as follows:
 Connect positive conductors 1 – 3 to ports *N1, *N2 and
*N3 9 – 11.
 Connect negative conductors 4 – 6 to ports *P1, *P2 and
*P3 13 – 15.
 Swap conductors connected to *N4 4 and *P4 12.
 Connect earthing cable between *N5 3 and DC earth connection
port.
Fig. 16 Connection positive-earthed PV string