After Startup; Exchanging Inverters - Platinum 2100 H Installation And Operating Manual

Hide thumbs Also See for 2100 H:
Table of Contents

Advertisement

8.2

After startup

If an inverter shows the installation menu, the startup of this inverter
has failed.
For all inverters in the CAN bus after startup:
 Check if startup was successful.
If startup has failed:
 Ensure that CAN cables are connected correctly.
 Ensure that DC switch is activated.
 Ensure that the power applied is >7 W
8.3

Exchanging inverters

Adding more inverters to a PV plant and replacing existing inverters is
possible.
Replacing a slave inverter
The master inverter will automatically detect the replacement and
start up the slave inverter.
The device number of the slave inverter will remain the same.
Replacing the master inverter
If the inverter to be replaced is a master inverter, and the master
function is desired:
 Configure an existing slave inverter as master
(see 9.9 Setup).
The inverter will perform an automatic logon sequence.
Installation and operating manual: PLATINUM inverter H
Version 01/2012
Mat. No. 753 840-AA
.
DC
PLATINUM inverter H
Start Up
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3000 h4000 h4600 h

Table of Contents