7

Connection of the inverter

Danger to life due to electric shock!
Â
Establish connections in the following order:
1. Network port
2. AC voltage port
Danger
3. DC voltage port
Danger to life due to high AC voltage!
Â
Open bottom cover of inverter exclusively if inverter is
de-energised and switched off.
Â
Switch off the mains power supply (AC side) before
Danger
switching off the inverter and secure it against
switching on (AC circuit breaker).
Â
Maximum allowed fuse on alternating voltage side:
40 A.
Â
Verify that galvanic isolation between the photovoltaic
generator circuit and the AC circuit is maintained by
the way the cables are run.
Â
Observe the trade associations' safety regulations.
Danger to life due to high DC voltage!
Â
Open bottom cover of inverter exclusively if inverter is
de-energised and switched off.
Â
Prior to connecting the inverter, verify that voltage is
Danger
present to the generator-side DC port.
Â
Prior to connecting the inverter, verify that the DC
voltage polarity is correct.
Â
Wear insulating protective clothing and face
protection if DC input.
Â
Remove DC cable exclusively if inverter is out of
operation and DC switch is deactivated.
Â
Use exclusively original MC4 removing tools for
removing cables.