Platinum 2100 H Installation And Operating Manual page 76

Hide thumbs Also See for 2100 H:
Table of Contents

Advertisement

PLATINUM inverter H
Operation
Load distribution
Active power
settings
Network
connection
76
Installation and operating manual: PLATINUM inverter H
Version 01/2012
Mat. No. 753 840-AA
Shows settings of phase distribution, based on set installation
country (country code).
Î
Name
t
Designation of grid standard of phase distribution
Î
Activated
t
Activate or deactivate phase distribution.
Î
Imbalance limit
t
Max. admissible difference between phases
Shows settings of configuration of power reduction (e. g. for the 70%
regulation), based on set installation country (country code).
Î
Name
t
Designation of grid standard of active power
Î
Activated
t
Activate or deactivate active power.
t
Active power setpoint
t
Fixed active power limit in W
Shows settings of basic parameters, based on set installation country
(country code).
Î
Name
t
Designation of grid standard
Î
V
coupling min.
AC
t
Minimum voltage for reconnection to grid
Î
V
coupling max.
AC
t
Maximum voltage for reconnection to grid
Î
f
coupling min.
AC
t
Minimum frequency for reconnection to grid
Î
f
coupling max.
AC
t
Maximum frequency for reconnection to grid

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3000 h4000 h4600 h

Table of Contents