  • Page 1 Installation and user guide Inverter 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL As at 10/2013, Material no. 747 405-AD...
  • Page 2 Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 3: Table Of Contents

    Isolation from the generator field Menu Operate and navigate in the menu Menu tree SETTINGS menu INfOrMATION menu Service menu Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 4 7 .1 Maintenance 7 .2 Cleaning Errors and troubleshooting Error display Event list Technical data Taking out of operation Disposal Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 5: Introduction

    1.3.1 Structure of warnings WArNING WOrD Type, source and consequence of the hazard! f Measures to avoid the hazard. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 6: Symbols On Product And Packaging

    Notes give tips on how to work easily and safely or contain further infor- mation. 1.4 Symbols on product and packaging The following sticker is attached to the inverter: Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 7: Safety

    ▪ Ensure that all protection devices are working correctly. ▪ Observe the operating conditions; see “Technical data” on page 48. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 8: Installation

    (2) out from the bottom of the box. 6. Set down the inverter. The supplied brief guide is located underneath the protector; see 13. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 9: Assembly

    PLATINUM GmbH recommends that the inverter should not be installed in living quarters. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 10 (3). 2. Grab the wall bracket (4) at the bottom and lift it up off the inverter. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 11: Mounting The Inverter

    1. Choose a suitable location for assembly. Take into account dimensions and distances. 2. fix the wall bracket to the assembly wall with suitable fixing materials. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 12 2. Ensure that the inverter is fitted correctly on the wall bracket. 3. Secure the inverter by tightening the safety screws (3) on the sides. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 13: Connection

    2. Take out the brief guide (7). 3. Hang the protector in one of the holders on the sides of the inverter. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 14 48. 2. Strip 18 mm of insulation from the AC voltage connection lines and add wire-end sleeves. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 15 5. feed the AC voltage connection line into the housing from below. 6. Tighten the AC screw connection. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 16 Do not ground the poles of the PV modules. The inverter does not have a transformer. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 17 Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 18 ▪ Twisted pair of wires of a CAT 5 cable Connect 1. Take off the cover (11) from the termi- nal strip. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 19 1. remove the terminating plug (12) from the protector. 2. Connect the terminating plug to socket 1 of the first and last inverter. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 20 24 V. The alarm contact can be configured in the menu SETTINGS –> ALArM fUNCTION; see 34. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 21 4. Slide the lower part of the protector into the lower holder. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 22: Placing Into Operation

    If data cannot be entered, the inverter displays the start screen. ▪ During initial operation, all inverters connected to the PLATINUM® network are blocked. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 23: Initial Operation Menu

    * The country code can only be changed for a period of four hours after initial operation and feed-in starts. This menu will not be displayed later. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 24 NO and continue to the next menu option. The automatic numbers for all inverters in the network are transferred. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 25 ▪ If different numbering is required, choose NO using the / buttons and choose OK to open the menu for changing device numbers. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 26 ▪ Grid support ▪ Power reduction * * These menus can only be changed 4 hours after initial configuration. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 27: Operation

    LED off Both LEDs flash at same time The inverter is running a network scan or making parameter settings. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 28: Operation Display

    ▪ Previous week ▪ Current month ▪ Previous month ▪ Current year ▪ Previous year ▪ Since initial operation Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 29 This display shows the actual (current) values for the voltage, current and power on the DC side and on the AC side. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 30: Isolation From The Generator Field

    On devices without a DC disconnect t Disconnect the DC side from the solar generator using the external isolation device. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 31: Menu

    ▪ return to the higher-level menu without making any changes ▪ Adopt setting and return to the higher-level menu ▪ Open selected submenu Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 32: Menu Tree

    Meter 2 Information Operating data System data Inverter type Inverter version The menu options are described in tables below. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 33: Settings Menu

    ▪ Set the alarm volume for the built-in buzzer on this inverter. 0 ... 3 Possible values: 0 ... 3 factory setting: 0 (alarm off) Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 34 Meter 2 counts the energy fed in since the last reset. ▪ Do not reset meter 2. Back ▪ reset meter 2. reset Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 35: Information Menu

    (9) firmware version (10) PLATINUM® Network version * ENS = Device for monitoring the network with allocated control elements Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 36: Service Menu

    See section 6.5.7 * These menus can only be changed for a period of 4 hours after initial configuration. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 37 Parameter 1007 , ▪ with submenus 1007 .0 and 1007 .0.0 ▪ with the current value for 1007 .0.0 Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 38 Q(U) hysteresis Q(U) closed-loop control according to the curve saved in the inverter. The curve can be parametrised via the PLATINUM® service tool. * from the perspective of a meter system Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 39 The red and green LEDs flash while the data is being saved. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 40 Power reduction Maximum Enter the maximum power for this inverter according to the power specifications of the network operator. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 41: Maintenance And Cleaning

    To ensure cooling, clean the ventilation slots regularly with ▪ a vacuum cleaner ▪ soft brush ▪ pressured air Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 42: Errors And Troubleshooting

    2. To exit the error display, press the  button. The event list is displayed. 3. Exit the event list by pressing the ESC button. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 43 1. To exit the error display, press the  button. The event list is displayed. 2. Exit the event list by pressing the ESC button. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 44: Event List

    ▪ Check isolation of PV cables and earth / PV– and earth ▪ AC installation (check N and PE) Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 45 ▪ Arrange for the network quality to be checked Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 46 ▪ Inform service of error code if required 4000 Diagnosis support in service situation 4990 The inverter stores the warning in the event list Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 47 Errors and troubleshooting Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 48: Technical Data

    3801 TL Max. efficiency 97 .7% 97 .7% Euro efficiency 97 .4% 97 .4% Type name 3800 TLD 3801 TLD Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 49 97 .4% 97 .4% 97 .4% 97 .5% 97 .5% 4300 TLD 4800 TLD 5300 TLD 6300 TLD 7200 TLD Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 50: Ambient Conditions

    IP66 in accordance with DIN EN 60529 the digital interface) Level of contamination II, external and internal use possible Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 51: Inverter Data

    ▪ 5300 TL, 6300 TL, 7200 TL The technical data is valid for a maximum height of 2,000 m above sea level. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 52: Taking Out Of Operation

    Ensure that the inverter is positioned securely. The procedure for taking inverters out of operation is the reverse of that for installation and assembly. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...
  • Page 53: Disposal

    ▪ PLATINUM® inverters can be disposed of via municipal waste management for electrical devices. Installation and user guide for PLATINUM® inverters 3800 TL, 3801 TL, 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL...