4.1.4 SP5-XXX (MODE)

5001
All Indicators On
All LEDs turn on. The LCD turns on or off every 3 seconds. Press the reset
5001 1
key to end this program.
5104*
A3/DLT Double Count
Selects whether the machine counts twice for each sheet of A3/11"x 17". If
5104 1
this is set to "Yes" is selected, the total (mechanical) counter and the current
user counter will both increment by two for each A3/11" x 17" sheet.
5113*
Optional Counter Type
5113 1 Selects the corresponding key for installed devices such as coin lock.
Clr-OP Count Remv
5120*
Determines under which conditions the copy job settings are reset when the
key counter is removed. With 0, the settings are cleared if the counter is
removed at the end of a job or midway through a job. With 1, they are only
5120 1
cleared if the counter is removed at the end of a job. With 2, they are not
cleared at all, under either condition. With duplex copies, the job settings are
always preserved, regardless of the setting of this SP mode.
5121*
Count Up Timing
Selects whether the key counter increments at time of paper feed-in or at
5121 1
time of paper exit.
SM Appendix
[0 = Enabled / 1 = Disabled /
2 = Disabled if the size is undetected]
0: None
11: MF key card (Increment)
12: MF key card (Decrement)
[0=Yes / 1=Standby only / 2=No]
[0 = Feed In / 1 = Exit]