  • Page 1 Unitech HT630 User's Manual User Manual Version 3 Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 2 Start. Please switch on the backup battery and to ensure fully charge the backup battery when you first time to use Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 3: Table Of Contents

    4.1 Specification of FormCaching...................16 4.2 How to Create a FormCaching.................17 4.3 How to Run FormCaching ..................17 4.4 Default Setting of FormCaching ................17 Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 4 Chapter 5 Bluetooth Application......................18 Chapter 6 WiFi settings ........................22 Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 5: Chapter 1 Introduction

    HT630 also has offer 3 different optional communication/charging cradles. These are RS232, Ethernet and Modem cradles. 1.2 Support Over here at unitech, making you satisfy is our first priority. If you find any problems regarding to this terminal or any our other product please feel free to contact us at www.unitech-utp.com.tw —Asia,...
  • Page 6: Technical Specification

    UPC/EAN, Code 39, Interleave 2 of 5, CODABAR, MSI, Code 128, Code 93, Code 32, China Postal Code Buzzer Yes, over 70 dB One LED Dual color; Green for good; Red for bad Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 7: Quick Start

    1.5 Quick Start This section is designed to let you quickly get familiar with HT630. If you need detail explanation on some of the functions, please refer to further chapters for detail explanation. HT630 Illustrations Figure 0-1: HT630 front view...
  • Page 8 During charging, LED above power icon will be displayed red. Once it is fully charged, LED will be turned to green. 2. Or, use the standard charging cable, which is packed with one of unitech HT630 packages or you can order them separately, together with the power adaptor. Connect the power plug of the adaptor to the charging cable, then, connect the charging cable to the main unit.
  • Page 9: Interface Ports

    1. 6 Interface Ports The HT630 does its’ communication via RS232 communication port located in the back of the unit. You can connect the unit via the communication cable to PC RS232 jack for data transfer or connect through cradle for communication.
  • Page 10: Using The Keyboard

    Figure 0-9: HT630 Keypad Legend Numeric mode The HT630 keyboard is initialized to normal mode after being powered on. In normal mode, the cursor is a block and the keyboard is mainly used to input numeric data and use F1-F4 four function-keys.
  • Page 11: Triggering Scanner Module

    To get “C”, press the same key 3 times. 1.8 Triggering Scanner Module The HT630 can be used with a built-in integrated laser scanner module to input data. The built-in decoder reads most barcode labels. Users should keep laser window clean to prevent low reading rate of distorted bar code input signal.
  • Page 12: Chapter 2 Power System

    RAM memory to prevent data-loss free environment. Normally, the HT630 gets power from main power source to back-up RTC and RAM; also puts the Lithium battery in standby state. When the main power source is removed or below the level to back-up the RAM and RTC properly, the power circuit of the HT630 automatically switches to the Lithium battery for back-up.
  • Page 13: Battery Replacement

    When the terminal shows “Main battery low” message, the battery needs to be recharged. Plug in the power adaptor into a power outlet and connect the other end to the power outlet of the HT630, mount the terminal into the cradle, LED light on the cradle will be in red, means in the charge. When the battery is fully charged, LED light will be in green.
  • Page 14: Storage And Safety Precautions

    If this happens, they will require recharging prior to use. Li-Ion batteries may be stored at temperatures between -4°F and 158°F (-20°C to 70°C). Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 15: Chapter 3 Operation

    Chapter 3 Operation The HT630 is set up several operating modes. The system of terminal may operate in various modes for different purposes. The figure below shows the operating flow of the terminal. The following diagram summarized these operating modes to switch between different modes.
  • Page 16: User Mode And System Commands

    This command deletes a file from RAM disk of terminal. After the file has <ERASE FILE > been deleted, it can not be recovered. SCAN.EXE Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 17: Configure The Terminal In Set Command

    The third line shows the current time. The way to set system time is similar to set system date described above. The format of system time is expressed in 24 hour of HH:MM:SS (hour:minute:second). Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 18 (Available only when HT630 in master mode) Reset Restore factory default settings. Exit Leave the BLUETOOTH setting environment. 3.3.6 EXIT: Leave the SET (setting) environment. Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 19 MULTI protocol and process to receive the data. For detailed description of each ESC command and protocol, please see the HT630 Programming Reference Manual. Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 20: Built-In Application- Formcaching

    TIME STAMP FIELD 1.NONE specify format of Time stamp 2.HHMM 3.HHMMSS FIELD DELAY specify time delay between each record input in second Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 21: How To Create A Formcaching

    NONE Field #2 FIELD PROMPT QTY: TIME STAMP FIELD NONE DATA LENGTH FIELD DELAY DATA TYPE NUMERIC DEVICE TYPE KEY ONLY Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 22 Chapter 5 Bluetooth Application HT630 can be configured to the standard Bluetooth HID as data output interface, which can allow the terminal to transmit and receive data via Bluetooth enabled devices. Follow the procedures below to establish a Bluetooth connection on the host.
  • Page 23 4. Right-click the HT630 icon and select “Pair Device”. 5. A window pops up asking for PIN Code. Enter the default PIN Code “1234” and click OK button. Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 24 6. Right-click the HT630 icon and select “Discover Available Services”. 7. Right-click the Dev B on HT630 icon and select “Connect to Bluetooth Serial Port”. Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 25 9. The icon turns to double arrows indicating the connected is ready. Now you can run applications or Windows Hyper Terminal on the host for testing. Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 26 Step 1: One should prepare an access point and change its SSID to wlandemo. Step 2: Once HT630 attached to Access Point, one may use Monitor.exe to Find HT630 & its IP address, even ones PC and HT630 are in different subnet.
  • Page 27 Change HT630's network, Basic Setup, Radio, Security and RS232 S etup settings by web browser. ote: Make sure ones PC is located on the same subnet as HT630. Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 28 Step 3: HT630's network, Basic Setup, Radio, Security and RS232 Setup settings should be configured in different web pages. Step 4: Click “Apply” button to save settings and make the change effective . Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 29 Note that you will not be prompted to enter the password if the HT630 is not currently password protected. 3. The HT630 homepage will open. On this page, you can see a brief description of the Web Console’s four function groups.
  • Page 30 Basic Setup HT630 WLAN supported IP configurations are Manual and dynamic (DHCP). Choose from two possible: IP configuration modes Manual and DHCP. Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 31 HT630. If the address is on the same subnet, a connection is established directly between the HT630 and the host. If the host is not on the same subnet, the packet is sent to the Gateway address.
  • Page 32 Select a radio channel for the wireless network from the pull-down menu. In infrastructure mode, the AP will specify the channel automatically. In Ad-hoc mode, the user must use the pull-down menu to specify the channel. Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 33 For each of the four WEP Keys, enter the appropriate WEP Key. The WEP Keys are used to help prevent data from being stolen as it is transmitted over public networks. The WEP Key setting(s) for the HT630 must be the same as the WEP Key settings for the AP.
  • Page 34 Finally, click “Apply” to save the change. (Also, if you desire to restore to the factory-set password, please click “Yes”. The default setting is disabled.) SNMP Setup Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 35 Reboot your HT630 and check whether the firmware has been upgraded in the Basic Information. Backup / Restore Settings HT630 provides backup and restore for file management. Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
  • Page 36 This button can be used to clear ALL data and restore ALL settings to the factory default values. Reboot AP In some cases, if you want to reboot HT630, click Yes and then apply. HT630 will reboot. Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.

Table of Contents