How To Create A Formcaching; How To Run Formcaching; Default Setting Of Formcaching - Unitech HT630 User Manual

Hide thumbs Also See for HT630:
Table of Contents

Advertisement

4.2 How to Create a FormCaching

FORMCACHING
1:YES
2:NO
OTHER:EXIT
You will need to enter Supervisor mode and select "4.FORM" category in order to set the configuration of
FormCaching (refer to the HT630 Programming Reference Manual for how to enter the Supervisor mode).
After selecting the "4.FORM" in Supervisor mode, the screen will show as above. The system will first ask
user to specify four categories of the field specification including field prompt, data length, data type and
device type of each data field. After completion to define all data fields, the user should hit [CMD] then
[ALPHA] keys to end the setup of field specification. This step also determines the number of fields in each
record and you may continue to set the rest six categories of record specification including between field, field
delimiter, record delimiter, date stamp field, time stamp field and field delay.
When the FormCaching application is executed, a data file named FORM.DAT will be created to store data.
The system will not allow the user to redefine FormCaching if the FORM.DAT is existed. It is necessary to
delete the FORM.DAT in order to change the configuration of FormCaching.

4.3 How to Run FormCaching

When FormCaching is enabled, the built-in application can be run by selecting "2.TER" command in User mode
and then select "2.FORMCACHING". The FormCaching application will follow the setting as defined to display
prompting, get input and store data in the file named FORM.DAT. Hit [CMD] then [ALPHA] keys to end
FormCaching and return to system Ready mode. User may use [ ] key to browse a previous data record, [ ] key
to step to next record, press [C] key to clear the record and then input new value of every field of this record.
After collecting data, the FORM.DAT file can be uploaded to host either by invoking Kermit server in User
mode described in section 3.2 or remote ESC command described in 3.4.

4.4 Default Setting of FormCaching

In default, the FormCaching is initialized with settings as shown in the table below.
DATA FIELD SPECIFICATION: field number=2
Category
Field #1
FIELD PROMPT
DATA LENGTH
DATA TYPE
DEVICE TYPE
Field #2
FIELD PROMPT
DATA LENGTH
DATA TYPE
DEVICE TYPE
Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
DATA RECORD SPECIFICATION
Setting
Category
ITEM:
BETWEEN FIELD
32
FIELD DELIMITER
ALPHANUM
RECORD FELIMITER
BOTH
DATE STAMP FIELD
QTY:
TIME STAMP FIELD
4
FIELD DELAY
NUMERIC
KEY ONLY
17
Setting
Append screen
,
CR
NONE
NONE
0

Advertisement