HT630 Product Reference Guide NOTICE This unit is equipped with a Li-ion battery pack. Battery power might be low due to storage. Recharge the battery when required. For procedures on 1.5 Quick Start how to charge the battery, please refer to Please note to switch on backup battery and to ensure fully charge the backup battery when you first time to use it.
These are RS232, Ethernet and Modem cradles. 1.2 Support Over here at unitech, making you satisfy is our first priority. If you find any problems regarding to this terminal or any our other product please feel free to contact us at; www.ute.com.tw—Asia, www.ute.com—America,...
HT630 Product Reference Guide 1.5 Quick Start This section is designed to let you quickly get familiar with HT630. If you need detail explanation on some of the functions, please refer to further chapters for detail explanation. HT630 Illustrations Figure 0-1:HT630 front view...
Page 7
During charging, LED above power icon will be displayed red. Once it is fully charged, LED will be turned to green. 2. Or, use the standard charging cable, which is packed with one of unitech HT630 packages or you can order them separately, together with the power adaptor. Connect the power plug of the adaptor to the charging cable, then, connect the charging cable to the main unit.
HT630 Product Reference Guide Cradle There are two ways to charge the main battery via the HT630 charging/communication cradle or a quick charging /communication cable. Cradle LED Icons The icon indicates communication. When HT630 is transmitting data with the host computer, LED will flash, showing that the data is transmitting.
Figure 0-9: HT630 Keypad Legend Numeric mode The HT630 keyboard is initialized to normal mode after being powered on. In normal mode, the cursor is a block and the keyboard is mainly used to input numeric data and use F1-F4 four function-keys.
HT630 Product Reference Guide 1.8 Triggering Scanner Module The HT630 can be used with a built-in integrated laser scanner module to input data. The built-in decoder reads most barcode labels. Users should keep laser window clean to prevent low reading rate of distorted bar code input signal.
RAM memory to prevent data-loss free environment. Normally, the HT630 gets power from main power source to back-up RTC and RAM; also puts the Lithium battery in standby state. When the main power source is removed or below the level to back-up the RAM and RTC properly, the power circuit of the HT630 automatically switches to the Lithium battery for back-up.
When the terminal shows “Main battery low” message, the battery needs to be recharged. Plug in the power adaptor into a power outlet and connect the other end to the power outlet of the HT630, mount the terminal into the cradle, LED light on the cradle will be in red, means in the charge. When the battery is fully charged, LED light will be in green.
HT630 Product Reference Guide It is important to consider the surrounding temperature whenever you are charging the Li-Ion battery pack. The process is the most efficient in the normal room temperature or slightly cooler. It is essential for you to charge battery within the stated range of 32°F to 113°F (0°C to 45°C).
HT630 Product Reference Guide Chapter 3 Operation The HT630 is set up several operating modes. The system of terminal may operate in various modes for different purposes. The figure below shows the operating flow of the terminal. The following diagram summarized these operating modes to switch between different modes.
HT630 Product Reference Guide 3.2 User Mode and System Commands There are eight system commands: RUN, TER, COM, DIR, ERA, TYP, CPY, and SET. Each command can be invoked through menu-selection in User mode. User can press [CMD] key for two seconds in Ready mode to enter User mode.
HT630 Product Reference Guide This command dumps the content of a file on the terminal's LCD. The content of the file will be displayed 128 (16 character x 8 line) characters at a time. Press any key to show the next page or hit [CMD] then [ALPHA] keys to return to User mode prompt.
Enable / disable bar code decoding PEN SCAN KEY When pen scanner is used on the HT630, you can setup whether pressing trigger key to enable pen scanner. If ENABLE is selected, you must press and hold down trigger to scan barcode label. If DISABLE is selected, you can directly scan barcode label without pressing trigger key.
HT630 Product Reference Guide Chapter 4 Built-in Application- FormCaching The system of terminal includes a built-in application, FormCaching. It allows you to create a data entry application from specifying field prompt, type, length, input method and delimiter, etc. without writing program and loading to the terminal.
You will need to enter Supervisor mode and select “4.FORM” category in order to set the configuration of FormCaching (refer to the HT630 Programming Reference Manual for how to enter the Supervisor mode). After selecting the “4.FORM” in Supervisor mode, the screen will show as above. The system will first ask user to specify four categories of the field specification including field prompt, data length, data type and device type of each data field.