Table 5-18 Processor Faults; Table 5-19 Bmc Faults; Table 5-20 Temperature Faults - HP Integrity rx2620 User's & Service Manual

Hp integrity rx2620 server user service guide
Hide thumbs Also See for Integrity rx2620:
Table of Contents

Advertisement

Table 5-18
Processor Faults
System
LED 1
LED
Flashing
RED
Red
Flashing
RED
Red
Flashing
RED
Red
Table 5-19
BMC Faults
System
LED 1
LED
Flashing
RED
Red
Flashing
RED
Red
Table 5-20
Temperature Faults
System
LED 1
LED
Flashing
RED
Red
Chapter 5
LED 2
LED 3
RED
GREEN
OFF
RED
OFF
GREEN
RED
GREEN
GREEN
LED 2
LED 3
GREEN
RED
GREEN
RED
LED 2
LED 3
GREEN
GREEN
Identifying and Diagnosing Hardware Problems
LED 4
Problem
Processor 0
temperature
exceeds limit
Processor 1
temperature
exceeds limit
No processor
detected.
LED 4
Problem
OFF
BMC
firmware is
damaged
GREEN
System
board FRU
inventory
device
inaccessible
LED 4
Problem
RED
External air
temperature
too high
Solution
Make sure nothing is blocking the
server's airflow and locate your
server in an air-conditioned room.
In a single CPU configuration,
verify that the airflow blocker is
installed.
Verify that the processor or
processors are correctly installed.
See the HP Integrity rx2620
Installation Guide, Chapter 3 for
installation procedures.
Solution
Turn off and unplug the server.
Wait 20 seconds, then plug in and
restart the server. If the error
repeats, replace the base unit.
View the SEL for additional
information.
Solution
Make sure nothing is blocking
the server's airflow and locate
your server in an
air-conditioned room.
Troubleshooting
127

Advertisement

Table of Contents
loading

Table of Contents