Hantek 1060 User Manual page 77

Handheld scopemeter dso1000 series
Hide thumbs Also See for 1060:
Table of Contents

Advertisement

banana jack input.
4) Connect the red and black leads to the measured point and the DC current value of
the measured point will be displayed on the screen.
5) Press F2 to return to 600 mA measurement.
Then, the screen will look like the following figure 4-8.
Figure 4-7 DC current Measurement for 600 mA
Making an AC Current Measurement
To measure an AC current which is less than 600 mA, do the following:
1) Press the A key and then DC appears on the screen. The unit on the main reading
screen is mA,and mA will display on the bottom of the screen, press F2 to switch the
measurement between mA and 10A. 600mA is acquiescently.
2) Press the F1 key once and AC will display on the bottom of the screen.
3) Insert the black lead into the COM banana jack input and the red lead into the mA
banana jack input.
4) Connect the red and black leads to the measured points and the AC current values of
measured points will be displayed on the screen.
Then, the screen will look like the following figure 4-10.
To measure an AC current which is larger than 600 mA, do the following:
1) Press the A key and then DC appears on the screen. The unit on the main reading
screen is mA.
2) Press F2 key to switch to10A measurement, the unit on the main reading screen is A.
5