Hantek 1060 User Manual page 21

Handheld scopemeter dso1000 series
Hide thumbs Also See for 1060:
Table of Contents

Advertisement

Menu
Setting
Enable
Coupling
Probe
1000X
Reset
1/2
2/2
Coarse
Volt/Div
Invert
BW Limit
2/2
1. Change Volt/DIV
It is the default setting of Volts/Div in a 1-2-5-step sequence from 10mV/div, 20mV/div,
50mV/div, to 1V/div,5 V/div or 10V/div.
The Volt/DIV will be displayed in the status bar on the bottom of the screen
Press CH1→Volt/Div→Coarse/Fine to Set Volt range.
ON
Turn on Channel
OFF
Turn off Channel
AC
The dc component in the input signal is blocked
DC
The ac and dc components of the input signal are allowed
GND
Disconnect the input signal
1X
Select one according to the probe attenuation factor to
10X
ensure correct vertical scale reading
100X
Set the vertical display position back to middle window
Go to the next menu page
Back to the previous menu page
Set Voltage range coarsely
Fine
Set Voltage range finely
ON
Turn on the invert function
OFF
Turn off the invert function
ON
Turn on the BW Limit
OFF
Turn off the BW Limit
Back to the previous menu page
Figure 2-2 Channel Volt/Div
Description