Set Trigger System - Hantek 1060 User Manual

Handheld scopemeter dso1000 series
Hide thumbs Also See for 1060:
Table of Contents

Advertisement

Set Trigger System

The trigger determines when the scope meter starts to acquire data and display a
waveform. When a trigger is set up properly, it can convert unstable displays or blank
screens into meaningful waveforms.
When the scope meter starts to acquire a waveform, it collects enough data so that it
can draw the waveform to the left of the trigger point. The scope meter continues to
acquire data while waiting for the trigger condition to occur. After it detects a trigger, the
scope meter continues to acquire enough data so that it can draw the waveform to the
right of the trigger point.
Trigger Modes
The scope meter provides seven trigger modes:
Edge
: An edge trigger occurs when the trigger input passes through a specified
voltage level in the specified slope direction.
Pulse
: Use this trigger type to catch pulses with certain pulse width.
Alternative
: Trigger on non-synchronized signals.
Edge Trigger Setting
An edge trigger determines whether the oscilloscope finds the trigger point on the rising
or the falling edge of a signal. Select Edge trigger Mode to trigger on rising edge, falling
edge or rising & falling edge.
TRIG → F1 → Edge
Press
table.
The Edge trigger menu
The Edge Trigger Table
Menu
Source
Slope
button to show the edge trigger menu as the following
Figure 2-26 The Edge trigger menu
Setting
CH1
Define CH1 or CH2 as trigger signal
CH2
Rising
Trigger on rising edge or falling edge
Falling
Edge, Pulse
Description
6
Alternative
and
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1200150016001600h