Dc606 Internal Print Test Patterns - Xerox Phaser 3635MFP Service Manual

Hide thumbs Also See for Phaser 3635MFP:
Table of Contents

Advertisement

dC606 Internal Print Test Patterns

Purpose
To print internal test patterns for image quality analysis.
Procedure
NOTE: Refer to IQ1 Image Quality Entry RAP for information on the test patterns.
1.
Enter diagnostics, GP 1.
2.
Enter Diagnostics Routines.
3.
Enter Other Routines.
4.
Enter 606 Print Test Patterns.
5.
Select Image Quality Test Patterns 1 - 19.
6.
Select the Features, 1 or 2 sided and the paper tray.
7.
Touch the Start Test.
General Procedures and Information
dC606
6-42
Draft 4
Phaser 3635MFP