4.2.7.2
ACT 4 actuator module
Connections
1) ACI*
2) Bus cable (to remote or electronics
module)
3) Bus cable (to remote or electronics
module)
4) Actuator - Channel 4
5) Actuator - Channel 3
6) Actuator - Channel 2
7) Actuator - Channel 1
* The ACI connection is used for actuator limitation or speed reduction.
4.2.8
R-NET ISM lighting and actuator module
A range of adjusting motors, also known as actuators, can be fitted to the wheelchair. These
actuators are either connected directly to the electronics module or to a separate actuator module.
The actuator module is connected with the electronics module via a bus cable.
In addition, the lighting can be connected to the R-NET ISM. An additional lighting PCB is not then
required.
Connections
1) Bus cable (to remote or ACT)
2) Light left
3) Adjusting motor/actuator - Channel 1
4) Adjusting motor/actuator - Channel 3
5) Adjusting motor/actuator - Channel 5
6) INH 4*
7) INH 5*
8) Adjusting motor/actuator - Channel 6
9) Adjusting motor/actuator - Channel 4
10) Adjusting motor/actuator - Channel 2
11) Light right
12) Bus cable (to remote or ACT)
* The INH connection is used for actuator limitation or speed reduction.
4.2.9
Lighting PCB
The lighting PCB connections are printed on the circuit board itself.
24
®