Programming
Make sure that your wall thermostat is well connected to the PC board #2. The main thermostat must be connected
to the "WOOD MECH" port on the PC board. The electric option's thermostat must be connected to the "USER
MECH" port on the PC board. The "WOOD24VAC" & "USER24VAC" ports are only necessary when connecting an
external appliance that shares the furnace blower (example : AC, heat pump).
In the MODE menu, select HEAT by pushing the SELECT button. Then, using the arrows buttons, choose from the
different selections: TEMP, or UNIT. Consult the "Selections" section in order to obtain a complete definition of the
terms TEMP, and UNIT.
When your choice is made, press SELECT. Then, use the arrows to make the appropriate adjustment. Press
SELECT to memorize your adjustment.
To change the selection (TEMP, or UNIT), push an arrow button. To go
back to the main menu (HEAT, COOL, CIRC, MANU), push on the MODE button. After two minutes of inactivity on
the keyboard, the display will shut itself off.

COOL Mode (air conditioning)

Operation
If an air conditioning unit is installed, the PC board #2 will have to be connected to a dual-function wall thermostat
(e.g. "heat/cool") in order to synchronize the start of the furnace blower with the start of the air conditioning
condenser. A switch installed on the PC board #2 will modify the reading of the wall thermostat's signal. Upon
receiving the wall thermostat's signal, the furnace blower will start functioning at the speed selected by the user.
Programming
Make sure that your wall thermostat is well connected to the PC board #2. The main thermostat must be connected
to the "WOOD MECH" port on the PC board. The electric option's thermostat must be connected to the "USER
MECH" port on the PC board. The "WOOD24VAC" & "USER24VAC" ports are only necessary when connecting an
external appliance that shares the furnace blower (example : AC, heat pump).
In the MODE menu, select COOL by pushing the SELECT button. Then, using the arrows buttons, choose from the
different selections: TEMP, UNIT, or FAN. Consult the "Selections" section in order to obtain a compete definition
of the terms TEMP, UNIT, and FAN.
When your choice is made, press SELECT. Then, use the arrows to make the appropriate adjustment. Press
SELECT to memorize your adjustment. To change the selection (TEMP, UNIT, or FAN), push an arrow button. To
go back to the main menu (HEAT, COOL, CIRC, MANU), push on the MODE button. After two minutes of inactivity
on the keyboard, the display will shut itself off.