which will change to pilot mode. When the temperature returns to a safe level, the blower speed gradually returns to
the speed required to maintain the BEP.
Programming
Make sure that your wall thermostat is well connected to the pellet central processing unit (Pellet CPU). The main
thermostat must be connected to the "WOOD MECH" port on the pellet central processing unit (Pellet CPU). The
electric option's thermostat must be connected to the "USER MECH" port on the pellet central processing unit (Pellet
CPU). The "WOOD24VAC" & "USER24VAC" ports are only necessary when connecting an external appliance that
shares the furnace blower (example : AC, heat pump).
In the MODE menu, select HEAT by pushing the SELECT button. Then, using the arrows buttons, choose from the
different selections: TEMP, or UNIT. Consult the "Selections" section in order to obtain a complete definition of the
terms TEMP, and UNIT.
When your choice is made, press SELECT. Then, use the arrows to make the appropriate adjustment. Press
SELECT to memorize your adjustment.
To change the selection (TEMP, or UNIT), push an arrow button. To go
back to the main menu (HEAT, COOL, CIRC, MANU), push on the MODE button. After two minutes of inactivity on
the keyboard, the display will shut itself off.

3.3.5 COOL MODE (AIR CONDITIONING)

Operation
If an air conditioning unit is installed, the pellet central processing unit (Pellet CPU) will have to be connected to a
dual-function wall thermostat (e.g. "heat/cool") in order to synchronize the start of the furnace blower with the start of
the air conditioning condenser. A switch installed on the pellet central processing unit (Pellet CPU) will modify the
reading of the wall thermostat's signal. Upon receiving the wall thermostat's signal, the furnace blower will start
functioning at the speed selected by the user.
Programming
Make sure that your wall thermostat is well connected to the pellet central processing unit (Pellet CPU). The main
thermostat must be connected to the "WOOD MECH" port on the pellet central processing unit (Pellet CPU). The
electric option's thermostat must be connected to the "USER MECH" port on the pellet central processing unit (Pellet
CPU). The "WOOD24VAC" & "USER24VAC" ports are only necessary when connecting an external appliance that
shares the furnace blower (example : AC, heat pump).
In the MODE menu, select COOL by pushing the SELECT button. Then, using the arrows buttons, choose from the
different selections: TEMP, UNIT, or FAN. Consult the "Selections" section in order to obtain a compete definition
of the terms TEMP, UNIT, and FAN.
When your choice is made, press SELECT. Then, use the arrows to make the appropriate adjustment. Press
SELECT to memorize your adjustment. To change the selection (TEMP, UNIT, or FAN), push an arrow button. To
go back to the main menu (HEAT, COOL, CIRC, MANU), push on the MODE button. After two minutes of inactivity
on the keyboard, the display will shut itself off.

3.3.6 CIRC (AIR CIRCULATION)

Operation
This mode is used to circulate air during summer. Thus you will benefit from your ducting system to circulate fresh
air from your basement throughout the house.
Programming
34