8.1 CHANGING OIL
Drain the oil while the engine is still warm to assure rapid and complete draining.
■Make sure to turn the engine switch and the fuel cap lever OFF
before draining.
1. Loosen the cover screw and remove the left side maintenance cover.
2. Remove the oil filler cap.
3. Drain dirty oil into a container thoroughly.
4. Refill with the recommended oil, and check the oil level.
5. Reinstall the left side maintenance cover and tighten the cover screw securely.