The DC receptacle may be used for charging 12 volt automotive-type batteries only, the zero load
voltage is 15V-30V.
1.Connect the charging cables to the DC receptacle of the generator and then to the battery
terminals.
■ In DC operation, turn the Smart throttle switch to the OFF position.
■To prevent the possibility of creating a spark near the battery,
connect charging cable first to the generator, then to the battery.
Disconnect cable first at the battery.
■Before connecting charging cables to a battery that is installed in a
vehicle, disconnect the vehicles grounded battery cable. Reconnect
the vehicle's grounded battery cable after the charging cables are
removed. This procedure will prevent the possibility of a short circuit
and sparks if you make accidental contact between a battery
terminal and the vehicle's frame or body.
■Do not attempt to start an automobile engine with the generator still
connected to the battery. The generator may be damaged.
■Connect the positive battery terminal to the positive charging cord.
Do not reverse the charging cables, or serious damage to the
generator and/or battery may occur.