PREFACE Thank you for purchasing our generators. This manual covers operation and maintenance of the IG1000, IG1000s generator. All information in this publication is based on the latest product information available at the time of approval for printing. We reserve the right to make changes at any time without notice and without incurring any obligation.
1. SAFETY INSTRUCTIONS 13. LIGHT KIT MOUNTING INSTRUCTIONS FOR: IG1000s LIGHT KIT Operate carefully and make sure users and others safety. WARNING WARNING M5 45 Our generators are designed to give safe and depend- able service if operated according to instructions. M5 16 Read and understand the Owner's Manual before op- erating the generator.
Page 6
To ensure safe operation-- 12. ELECTRIC DIAGRAM WARNING Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped. Parallel output Keep away from cigarette, smoke and sparks when re-fueling the generator. Always refuel in a well-ventilated location.
2. SAFETY LABEL LOCATIONS 11. SPECIFICATIONS SPECIFICATIONS These lables warn you of potential hazards that can cause serious injury. Read Model IG1000/IG1000s the labels and safety notes and precautions described in this manual carefully. Rated frequency (Hz) If a label comes off or becomes hard to read, contact your dealer for a Rated voltage (V) replacement.
Appliance does not operate: 3.COMPONENT IDENTIFICATION Is the output indicator light ON? Take the generator to an Fuel cap lever Is the overload indicator light ON? authorized dealer. Choke lever Check the electrical appli- Control panel Take the generator to an ance or equipment for any authorized dealer.
Page 9
Control panel 10.TROUBLESHOOTING Smart Throttle switch Output indicator light DC receptacle When the engine will not start: Overload indicator light Is there fuel in the tank? Refill the fuel tank. Low oil alarm indicator light Ground terminal Turn the engine switch on. Is the engine switch on? AC receptacle Parallel...
a. Drain all gasoline from the fuel tank into an approved gasoline container. 4.PRE-OPERATION CHECK b. Turn the engine switch ON, and loosen the carburetor drain screw and drain the gasoline from the carburetor into a suitable container. c. With the drain screw loosened remove the spark plug cap, and pull the starter CAUTION grip 3 to 4 times to drain the gasoline from the fuel pump.
Page 11
9.TRANSPORTING/STORAGE Upper lever To prevent fuel spillage when transporting or during temporary storage, the genera- Upper limit Oil rule tor should be secured upright in its normal operating position, with the engine switch OFF. Turn the cap lever fully counterclockwise to the "OFF" position. WARNING Oil filler hole Lower limit...
Page 12
Fuel tank capacity:2.6L 3.Use a brush to remove carbon deposits from the spark arrester screen. Open Fuel filler cap Oil surface Spark arrester Gasoline containing alcohol If you decide to use a generator containing alcohol (gasohol), be sure it's octane rating is at least as high as that recommended by us.
Page 13
4.SPARK ARRESTER MAINTENANCE(Equipped type only) 3.Check the air cleaner. Check the air cleaner element to be sure it is clean and in good condition. WARNING Loosen the cover screw and remove the left side maintenance cover. Press the latch tab on the top of the air cleaner body, remove the air cleaner cover, check If the generator has been running, the muffler will be very hot.
5.Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. 5.STARTING THE ENGINE Clean the spark plug with a wire brush if it is to be reused. 6.Measure the plug gap with a feeler gauge. The gap should be 0.6-0.7mm(0.024-0.028in). Correct as necessary by carefully NOTE bending the side electrode.
Page 15
3.Move the choke lever to the START position. 3.SPARK PLUG SERVICE RECOMMENTED SPARK PLUG: UR5/A7RTC NOTE To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. Do not use the choke when the engine is warm or the air temperature is 1.Remove the spark plug maintenance cover.
Page 16
5. Move the choke lever to the RUN position after the engine warms up. 2.AIR CLEANER SERVICE A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction,service the air cleaner regularly. Service more frequently when Choke lever operat-ing the generator in extremely dusty areas.
1.CHANGING OIL 6.GENERATOR USE Drain the oil while the engine is still warm to assure rapid and complete draining. CAUTION Make sure to turn the engine switch and the fuel cap lever OFF before WARNING draining. To prevent electrical shock from faulty appliances, the generator should be 1.Loosen the cover screw and remove the left side maintenance cover.
Page 18
8.MAINTENANCE NOTE The DC receptacle can be used while the AC power is in use. If you use both at the same time, be sure not to exceed the total power for AC and DC. The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition.
Page 19
Output and Overload Indicators Oil Level Indicator 3.Turn the cap lever fully counterclockwise to the "OFF"position. The output indicator light(green)will remain ON during normal operating conditions. If the generator is overloaded(in excess of 1.0kVA), or if there is a short in the con-nected appliance, the output indicator light(green) will go OFF, the overload indica-tor light(red) will go ON and current to the connected appliance wil be shut off.
1.Connect the ground terminal. 7.STOPPING THE ENGINE To stop the engine in an emergency, turn the engine switch to the OFF position. IN NORMAL USE: 1.Switch off the connected equipment and pull the inserted plug. Ground terminal 2. Start each engine according to "STARTING THE ENGINE". When the output indicator light(green)does not light and the overload indicator light (red) lights instead,set the engine switch to STOP,stop the engine at once Plug...
Page 21
Low oil alarm system 4.Switch on the equipment to be used. The Low oil alarm system is designed to prevent engine damage caused by an In case of overload operation or when trouble occurs for the equipment being insufficient amount of oil in the crankcase. Before the oil level in the crankcase used, the output indicator light(green) will go out, the overload indicator light(red) falls below a safe limit, the Low oil alarm system will automatically shut down the will light continuously, and no power will be put out.
Page 22
1.Connect the charging cables to the DC receptacle of the generator and then to WARNING the battery terminals. The battery gives off explosive gases; keep sparks, flames and cigarettes away. Provide adequate venti-lation when charging. The battery contains sulfuric acid (electrolyte). Con-tact with skin or eyes may cause severe burns.