Dip Switch Setup - Genie CCTV ASD276 Instruction Manual

Vandal resistant ptz day/night camera
Table of Contents

Advertisement

DIP Switch Setup

Before installing the camera, set up the DIP switch to configure the camera ID and the
communication protocol.
Camera ID Setup
ON
ON
1
2
3
4
Speed Dome Camera Instruction Manual
ID numbers of cameras are set up with binary numbers.
See the examples shown below.
Pin
5
6
7
8
Binary Value
example ID=5
example ID=10
The camera ID range is "1~255". Camera ID must not be
"0"!
The factory default of the camera ID is "1".
Match the camera ID with the Cam ID setting of the DVR
or Keyboard Controller to control the camera.
If you are connecting a single camera to a controller,
terminate the camera. When connecting more than one
camera to a single controller, terminate the last camera on
the communication line. The last camera means the camera
farthest in cable length from the controller.
Note that the total length of the communication cable
between a controller and the camera(s) on the same
communication line must be less than 1.2Km.
INSTALLATION
1
2
3
4
1
2
4
8
on
off
on
off
off
on
off
on
2
5
6
7
8
16
32
64
128
off
off
off
off
off
off
off
off