Lenovo ThinkServer RD450 User Manual And Hardware Maintenance Manual page 180

Hide thumbs Also See for ThinkServer RD450:
Table of Contents

Advertisement

2. Ensure that all internal cables are connected and routed correctly and secured by any cable clips or
ties in the server. Keep cables clear of the hinges and sides of the chassis to avoid interference with
reinstalling the cooling shroud and the server cover. The following illustration shows an example of the
cable routing in the chassis for server models with an optical drive and an internal tape drive installed.
• Properly route the power cable
• Properly route the cable
• Properly route the cable
and the AnyRAID adapter.
• Route the signal cables
following:
– SATA signal cable from the optical drive to the corresponding SATA connector on the system board
– Cables from the front panel board to the front panel connectors on the system board
– Cable from the AnyRAID adapter to the AnyRAID connector on the system board
Figure 153. Cable routing
3. If you have removed the cooling shroud, reinstall it. See "Removing and reinstalling the cooling shroud"
on page 64.
166
ThinkServer RD450 User Guide and Hardware Maintenance Manual
1
for the backplane through the right inner side of the chassis.
2
that is connected from the optical drive to the front backplane.
3
that is connected from the internal tape drive to the front backplane
4
through the left inner side of the chassis. The signal cables include the
4
1
2
3