4.2 Error Messages

Code
Message
E00
Communication error
E04
Feature not available
E06
Missing argument
E11
Disc is not loaded
E12
Search error
E13
De-focusing error
E15
Picture stop
E16
Other device input
E99
Panic
Figure 4-C
LD-V8000 Level I & III User's Manual
LD-V8000 Level I & III • Chapter Four
Meaning
Communication line error,
framing error, buffer overflow error.
Non-usable function has been tried.
The command mnemonic is wrong.
A command specific to CAV or CLV is sent
while the wrong type of disc is in the drawer.
Necessary parameter is not specified.
There is no disc in the drawer.
Search or Stop Marker address cannot be found.
Laser error: Unfocused
Playing has been stopped by a picture stop
code.
The command(s) sent via the serial line, were
not executed before commands were sent
from the front panel keys, the RCU and/or
before a Level II program could be executed.
Unrecoverable error occurred
loaded. Playing cannot be continued.