Mixed Input/Output Example; Figure B.3: Sinking Output To Relay; Figure B.4: Mixed Output Example- Standard I/O Set - IMS Mforce micro drive Reference

Motion control
Table of Contents

Advertisement

Sinking Output
Internal
pull-up
voltage
always
off
switched
Sinking Output Equivalent Circuit
Application Example
Active LOW Output will be opem a relay, useful for Fault.
'[VARIABLES]
S1=19,0,0

Mixed Input/Output Example

S Parameter Settings
S1 = 16,0
S2 = 4,1,1
S3 = 2,0,0
S4 = 3,0,0

Figure B.4: Mixed Output Example- Standard I/O Set

Appendices
MForce Plus
IOx
24.9k ohms
GND

Figure B.3: Sinking Output to Relay

'Configure IO 1 as a Fault output.
LOAD
IO1
GO
IO2
+ LIMIT
IO3
- LIMIT
IO4
GND
*External Resistor may be needed to
limit output sink current to 600mA
Sinking Output
+
up to
24 V
PNP
+
up to
+24 V
NOTE: On the
Standard MForce
Plus, when configured
as outputs, the I/O
set is sinking ONLY! The Plus 2
Models add the functionality of
I/O Power, which enables the
user to use all the outputs, both
Standard and Enhanced, as
Sinking or Sourcing.
A-7