Dedicated Digital I/O - Enhanced I/O Set; Step/Direction/Clock I/O; Figure 2.4.14: Step Direction I/O Equivalent Circuit - IMS Mforce micro drive Reference

Motion control
Table of Contents

Advertisement

Dedicated Digital I/O - Enhanced I/O Set

Step/Direction/Clock I/O

These dedicated I/O lines are used to
receive clock inputs from an external device
provide clock outputs to an external device
such as a counter or a second MForce
MicroDrive in a system.
The Clock I/O can be con-
figured as one of three clock types using the
S7 and S8 variable:
1. Step/Direction
2. Quadrature
3. Up/Down
Step/Direction
The Step/Direction function
would typically be used to receive
step and direction instructions
from a second system MForce
or secondary controller. When
configured as outputs the MForce
can provide step and direction
control to another system drive
for electronic gearing applications.
Quadrature
The Quadrature clock function
would typically be used for
following applications where
the MForce would either be a master or slave in an application that would require two MForce
MicroDrives to move the same distance and speed.
Up/Down
The Up/Down clock would typically be used in a dual-clock direction control application, or to
increment/decrement an external counter.
V in Max = +5 V
V in Hi = 1.86 V
V in Low = 0.9 V
I in Hi
= 1 mA
I in Low = -0.8 mA
V o Min = 2 V
V o Max = 5 V
Iosc Min = 35 mA
Iosc Max = 250 mA
Step Clock/Channel A/Clock Up
Direction/Channel B/Clock Down
When used as an input a
10kΩ Bias resistor is
required.
Part 2: Connections and Interface
Step/Direction Function
Quadrature Function
Up/Down Function
Figure 2.4.13: MForce MicroDrive Clock Functions
MForce
Step Out
T
Step In
R
Dir Out
T
Dir In
R
IOGND

Figure 2.4.14: Step Direction I/O Equivalent Circuit

Input:
S<7-8>=33, <active state>
Output: S<7-8>=49,<active state>
Step Clock
Direction
Input:
S<7-8>=34, <active state>
Output: S<7-8>=50,<active state>
Channel A
Channel B
Input:
S<7-8>=35, <active state>
Output: S<7-8>=51,<active state>
CW
CCW
STEP_IO
ENABLE SDIO
DIR_IO
NOTE: Advanced
I/O interface circuit
diagrams and
application examples are
or
available in the I/O Application
Guide Appendix.
NOTE: When
using the MForce
MicroDrive2 with the
external encoder
option, the step an direction
I/O are not available! These I/
O points become Index + and
Index -. See the Closed Loop
Control Appendix for encoder
connection and configuration
information.
WARNING: The
Clock I/O and
Capture/Trip
I/O are TTL Level
compatible. DO NOT Exceed
+5VDC!
2-33