(2) The following table describes the key functions displayed on the BM Monitor screen.
Key switch
Activates the Quick test operation.
TEST
Subsection 14.2.8 Quick test operation of monitor devices
Switches the screen to the functional change menu screen to activate another monitor function or terminate the system
monitor function.
MENU
Subsection 14.2.9 Changing screens (common operation)
Switches the screen to the display format switching screen to change the value display format (DEC/HEX) on the BM
Monitor screen or comment/no-comment display.
FORM
Subsection 14.2.7 Switching the display format (DEC/HEX) and comment/no-comment display
Switches the screen to the Device entry screen to enter or test monitor devices.
Entering monitor devices:
SET
Test operation:
Scroll displayed information upward or downward by a line to display the preceding or next monitor device that is not
currently displayed. When five or more monitor devices are entered, these switches are available when their comments
are displayed.
: Scrolls information upward by a line.
: Scrolls information downward by a line.
(3) The following table below describes the range of display of items 1) to 7) displayed.
No.
Item
1)
Network No.
2)
Station No.
3)
CPU No.
4)
Word device value
5)
Device No.
6)
Device name
7)
Monitor display area
*1:
Indicates CC-Link connection (via G4).
14.2.22 Information displayed on the BM Monitor screen and key functions
Function
Subsection 14.2.5 Entering monitor devices (specifying monitor stations and
devices)
Subsection 14.2.24 Test operation
Bus connection
0 to 4: This item must be set only when the system is connected to multiple QCPUs. It is not
necessary when the system is connected to another CPU.
[Decimal number]
four digits (including a digit for a sign) are displayed. (Display example: 1234)
[Hexadecimal number]
four digits are displayed. (Display example: H AB12)
Up to 16 devices can be entered. (When the CPU is an FXCPU, devices cannot be entered.)
For further information about device numbers and names that can be entered:
GT Designer 2 Version
GT Designer 3 Version
Up to 16 devices can be displayed at a time.
Description of setting
Direct CPU
Computer link
connection
connection
0
FF
Screen Design Manual
Screen Design Manual (Fundamentals)
14.2 System Monitor
9
10
11
12
CC-Link
connection
13
1
G4 *
FF: When the
host station
is selected
0: When the
master
station is
14
selected
1 to 64: When a
local station
is selected
15
16
14 - 41