Protocol Page

This page is for changing the HTTP server port number.
This page can be used during access using admin .
● Click [Advanced Settings] to display setting menu.
● Click [Protocol]. Press the [OK] button to enable the new settings.
● Press the [OK] button to enable the new settings.
● After changing, you will need to re-establish the connection if you are using the Internet Explorer.
Click
A
HTTP Server
Port
B
VISIP Protocol
C
HTTP Server
Port
D
AMX Device
Discovery
Protocol
:
Memo
● If Built-in Viewer is used for playback, change the [HTTP Port] number in the setting screen of Built-
in Viewer to the same value. (A Page 119)(A Page 121)
You can change the port number for the built-in web server of the camera.
(1-65535)
The default port number setting is 80 . The port number of JPEG/MPEG4
server is changed also.
To access to camera from the Internet Explorer, enter the following in the
Internet Explorer when the camera is in its default settings.
http://192.168.0.2
If the port number is changed to 8080 , for example, enter the Internet
Explorer as follows.
http://192.168.0.2:8080
You can change the On/Off setting of VSIP Protocol. To use this unit from
Nextiva of Verint Systems Inc., select On .
You can change the port number for Built-in VSIP server of the camera.
(1-65535) The default port number setting is 5510 .
You can change the On/Off setting of AMX device detection protocol. Set to
On when you are using the camera on AMX's systems.
[Setting value:On , Off]
A
B
C
D

Hide quick links: