JVC LST0819-001A Instructions Manual page 77

Ptz ip dome camera
Table of Contents

Advertisement

A
Display Screen
B
Detection
C
OK/Cancel
D
Level
E
Mask All
F
Clear Mask
:
Memo
● The area display position serves as a reference. Make sure to perform operation check.
● The screen is divided into blocks of 96 (12 horizontal x 8 vertical). Set the angle of view such that the
size of the object for which motion is to be detected is larger than the size of multiple blocks.
● When [Stabilizer] is set to On , the image is zoomed to 1.3 times. Thus, the number of blocks
displayed on the motion detection setting screen becomes 48 (8 horizontal x 6 vertical).
(A Page 53)
Note:
● Flickers of fluorescent lamps may cause motion detection.
● Changes in brightness due to the light source may be detected as motion.
● The motion detection feature is not intended to prevent theft or fire. This feature may not function
properly depending on the conditions of the object and settings.
Our company shall not be liable for any accident or damage that occurs.
● When other client is getting JPEG/MPEG4 stream from this unit, video images may not appear on
the [Motion Detection] page due to the maximum distribution limit of the camera. Stop other clients
before using the [Motion Detection] page.
The screen is divided into blocks of 12 (horizontal) x 8 (vertical). Use this to
set whether to mask each block.
All blocks are masked in the default setting.
The block turns blue when it is clicked, indicating that it is unmasked. Click
again to return to the masked state.
Press the [OK] button to enable this setting.
Use the [Mask All] button to mask all blocks.
Use the [Clear Mask] button to unmask all blocks.
For setting the On/Off of [Detection].
Press the [OK] button to enable this setting.
Motion detection does not work during [Auto Tracking/Intelligent Tracking]
(A Page 67).
To apply the new parameters, press the [OK] button.
Press the [Cancel] button to cancel the change.
For setting the sensitivity of motion detection.
Increasing the number raises the detection sensitivity level, and hence it is
more sensitive.
Press the [OK] button to enable this setting.
[Setting value:0 to 10]
Masks all blocks.
Press the [OK] button to enable this setting.
Unmasks all blocks.
Press the [OK] button to enable this setting.