Section 3: Operation
System Configuration
— COMMUNICATIONS —
3-36
'
Settings in the Communications
submenu define and control how
single or multiple projectors are
can link with each other and with a
controlling device.
Baud Rates
The baud rate setting determines
the speed of communication to and
from the projector on the RS232 or
RS422 links. The maximum rate
for either standard is 115200. Set
the baud rate to match that of your
controlling device, such as your PC. If you are unsure about what baud rate to choose,
refer to the documentation for the controlling device. In an existing network of
projectors, if you discover that a projector has a different baud rate, make sure to use
the pull-down list and select the correct baud rate using the
scroll this control with
no parity.
Projector
Enter a three-digit number (such as "001") to assign or change a number to the
projector currently in use. If the current projector already has a number assigned, that
number will appear here (for example, "004" in Figure 3.14, above). Numerical
identity for projectors enables you to communicate with a single projector within a
multiple-projector application (see also
make a mistake in assigning or changing the projector number, press
Network Routing
NOTES: 1) Not applicable for stand-alone projectors or simple serial networks with
only one type of controller and linking.
Select "Separate" (factory default) to keep RS232, RS422 and Ethernet
SEPARATE:
messages on their respective paths instead of being broadcast to the other types of
ports. In Figure 3.15A, RS422 controls only the projector to which it is connected. In
Figure 3.15B, either RS232 or RS422 will control the network.
or
keys. Serial communication is always 8 data bits,
Proj
User's Manual
Figure 3.14. Communications
key—do not just
key in 3.2, Using the Keypads). If you
to cancel.
Exit