Ricoh B156 Service Manual page 713

Gestetner, lanier, savin
Table of Contents

Advertisement

Address
68057B
Not used
to
680580
680581
Interval between dialing the last digit
and switching the Oh relay over to
the external telephone when dialing
from the operation panel in handset
mode.
680582
Bits 0 and 1 - Handset off-hook detection time
Bit
1 0 Setting
0 0 200 ms
0 1 800 ms
Other Not used
Bits 2 and 3 - Handset on-hook detection time
Bit
3 2 Setting
0 0 200 ms
0 1 800 ms
Other Not used
Bits 4 to 7 - Not used
680583
Not used
to
6805A0
6805A1
Acceptable CED detection frequency
upper limit (high byte)
6805A2
Acceptable CED detection frequency
upper limit (low byte)
6805A3
Acceptable CED detection frequency
lower limit (high byte)
6805A4
Acceptable CED detection frequency
lower limit (low byte)
6805A5
CED detection time
6805A6
Acceptable CNG detection frequency
upper limit (high byte)
6805A7
Acceptable CNG detection frequency
upper limit (low byte)
6805A8
Acceptable CNG detection frequency
lower limit (high byte)
6805A9
Acceptable CNG detection frequency
lower limit (low byte)
6805AA
Not used
6805AB
CNG on time
6805AC
CNG off time
6805AD
Number of CNG cycles required for
detection
6805AE
Not used
SM
CÓPIA NÃO CONTROLADA
Function
99
CÓPIA NÃO CONTROLADA
NCU PARAMETERS
Unit
Remarks
Do not change the
settings.
20 ms
Factory setting: 500 ms
Do not change the
settings.
BCD (Hz)
If both addresses contain
FF(H), tone detection is
disabled.
BCD (Hz)
If both addresses contain
FF(H), tone detection is
disabled.
20 ms
Factory setting: 200 ms
± 20 ms
BCD (Hz)
If both addresses contain
FF(H), tone detection is
disabled.
BCD (Hz)
If both addresses contain
FF(H), tone detection is
disabled.
Do not change the
setting.
20 ms
Factory setting: 500 ms
20 ms
Factory setting: 200 ms
The data is coded in the
same way as address
680533.
Do not change the
settings.
B750