SP2-XXX: (Drum)

Mode No.
2
(Class 1, 2, and 3)
001*
Charge Bias
1
[M]
2
[C]
3
[Y]
4
[K]
5
No Image Area
6
Charger Current
100*
Magnification Adjustment
1
Main Scan
2
Sub Scan
101*
Trim Adjustment
1
front
2
back
3
lead
4
trail
201*
Develop Bias Adjustment
1
[M]
2
[C]
3
[Y]
4
[K]
208
Forced Toner
1
[K]
2
[C]
3
[M]
4
[Y]
5
All Color
213
Toner End Set
Toner End Set
306
Trans Belt First
1
1 Color
2
2/3/4 Colors
400*
Cleaning Bias LL1
1
1 Color
2
2 Colors-4 Colors
3
Half Speed/1 Color
4
Half Speed/2 Colors-4
Colors
5
ID pattern
6
No Image Area
SM
CÓPIA NÃO CONTROLADA
Adjusts the charge corona unit grid voltage.
[300 ~ 800 / 500 / 1 Volt/step]
Only effective if process control is disabled.
Adjusts the charge corona unit current.
[400 ~ 800 / 500 / 1 µA/step]
Adjusts the magnification in each scan direction.
[–12.8 ~ 12.7 / 0 / 0.1%/step]
Adjusts the width of the white margin.
[0.0 ~ 9.0 / 4.0 / 0.1 mm/step]
[0.0 ~ 9.0 / 2.0 / 0.1 mm/step]
Adjusts the development bias.
[0 ~ 500 / 250 / 1 Volt/step]
Only effective if process control is disabled.
Forcefully supplies toner to the development unit.
Specifies how many sheets can be printed after the
toner near end message.
[0 ∼ 255 / 50 / 1 /step]
Adds the transfer current to the first page to improve
insufficient transfer of the whole solid image.
[3.0 ~ 14.0 / 9.0 / 1 µA /step]
[3.0 ~ 14.0 / 13.0 / 1 µA /step]
Adjusts the transfer belt cleaning voltage when absolute
humidity AH (g/m
0 < AH ≤ 3.5 (this is the 'LL1' humidity range)
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
5-9
CÓPIA NÃO CONTROLADA
SERVICE PROGRAM MODE
Function / [ Setting ]
3
) is in the following range:
B156/B220