Page 1
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual...
Page 2
AXIOMTEK assumes no responsibility for any inaccuracies that may be contained in this document. AXIOMTEK makes no commitment to update or to keep current the information contained in this manual. AXIOMTEK reserves the right to make improvements to this document and/ or product at any time and without notice.
Page 3
Trademarks Acknowledgments AXIOMTEK is a trademark of AXIOMTEK Co., Ltd. IBM is a registered trademark of International Business Machines Corporation. MS-DOS, Microsoft C and QuickBasic are trademarks of Microsoft Corporation. TURBO C is a trademark of Borland Inc. BASIC is a trademark of Dartmouth College.
ESD Precautions Integrated circuits on computer boards are sensitive to static electricity. To avoid damaging chips from electrostatic discharge, observe the following precautions: Do not remove boards or integrated circuits from their anti-static packaging until you are ready to install them. Before handling a board or integrated circuit, touch an unpainted portion of the system unit chassis for a few seconds.
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual Chapter 1 Introduction 1.1 Introduction 4U Industrial workstation with 8.4" LCD & 14 slots backplane. The ICS-480V is a 4U 14-slots Rackmount Workstation with 8.4" LCD display and Front panel function &...
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual 1.2 General Specification • Construction: Heavy duty steel chassis • Drive bay: Shock-proof and front accessible 5.25" by three drive bays. • Cooling system: Single 86 CFM cooling fan with top-accessible air filters •...
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual Chapter 2 System Setup 2.1 System Installation WARNING: Before starting the installation process, be sure to shut down all power from the chassis. Do this by turning off the power switch, and unplugging the power cord from the power outlet.
User’s Manual 2.1.2 Chassis Front and Rear Sections Face to the front view of ICS-480V, you will find a 8.4" TFT display module. There is a front door on the left side of the front panel, which has 12 function keys and 65 data entry keys on it.
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual 2.1.3 Front Control System Reset: Press this switch to reinitialize the system. This is the same as the hardware reset button. Power On/Off Switch: Use this switch to turn on/off the system power.
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual 2.1.4 Drive Bay Installation The standard type of the drive bay of ICS-480V can hold up to three external 5.25" devices (or two 5.25" and one 3.5" devices) and one 3.5" HDD. Axiomtek also offer the 5.25"...
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual 2.1.5 CPU card Installation To install slot board computers and other add-on boards: 1. Remove the chassis cover. 2. Take out the hold down cramp 3. Insert the SBC or add-on cards on suitable loca- tion 4.
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual 2.1.6 Cable connection for CPU card There four cables come with the ICS-480 barebone; HDD LED, Reset Switch, Speaker, and Keyboard Lock. Please refer to your SBC manual to connect these four jumpers to the SBC.
Page 17
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual C. Rear Keyboard A. Power for System Fan and A/D board B. Keyboard Transmitter D. Power Switch Figure 2.8: Cable Connection System Setup...
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual 2.3 Power Supply ICS-480V is with a power supply bracket; please use this bracket for PS/2 power and remove this bracket if you want to install redundant power supply.
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual 2.4 Air Filter Replacement There is one Cooling Fans located inside the chassis behind the LCD. The Air Filter is easy to maintain. To replace the Air Filter please refer to Figure 2.11 a.
The ICS-480V is an innovation version workstation, which supports most Single Board Computer from most IPC vendors. AXIOMTEK had integrated the VGA A/D board to the ICS-480V. As long as the SBC has the industrial standard 9-pin D-sub, it can be installed in the ICS-480V.
Page 21
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots Backplane User’s Manual Main Menu Range of Control Brightness 0~100 Contrast 0~100 Horizent Position 0~100 Vertical Position 0~100 Phase 0~100 Dimming 0~100 Reset Reset to default value Exit OSD System Setup...
Page 22
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual Appendix A Safety Instructions B.1 Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User’s Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning.
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual a. The power cord or plug is damaged. b. Liquid has penetrated into the equipment. c. The equipment has been exposed to moisture. d. The equipment does not work well, or you cannot get it to work according to the user’s manual.
Page 24
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual 18. The computer is provided with appropriate safety standards including lec 60826. 19 Install the computer. Before your begin make sure the Green/Yellow wire reliable connection between metal part of computer and earthing of final system.
Page 25
ICS-480V 4U Industrial Workstation with 8.4” LCD and 14 slots backplane User’s Manual Safety Instructions...
Need help?
Do you have a question about the ICS-480V and is the answer not in the manual?
Questions and answers