Vari Lite VL1000 ERS Luminaire User Manual
Hide thumbs Also See for VL1000 ERS Luminaire:
Table of Contents

Advertisement

Quick Links

VL1000
ERS Luminaire
®
U
'
M
SER
S
ANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Vari Lite VL1000 ERS Luminaire

  • Page 1 ™ VL1000 ERS Luminaire ® ’ ANUAL...
  • Page 2 ® VARI❋LITE is a trademark owned by Genlyte Thomas Group LLC and is registered in the United States and other countries. ™ ™ VL1000™, VL2000™, VL2201™, VL2202™, VL2400™ (and the individual product designations), VL3000™, Series 1000 , Series 2000 ™ ™...
  • Page 3 OREWORD How To Obtain Warranty Service A copy of the Vari-Lite Limited Warranty was included in the shipping package for this VARI❋LITE® product. To obtain warranty service, please contact customer service at 1-877-VARI-LITE (1-877-827-4548) or +1-214-647-7880 or via e-mail at customerservice@genlyte.com and request a Return Material Authorization (RMA) for warranty service.
  • Page 4 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Compliance Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment.
  • Page 5 OREWORD Safety Notice It is extremely important to read ALL safety information and instructions provided in this manual and any accompanying documentation before installing and operating the products described herein. Heed all cautions and warnings during installation and use of this product. Safety symbols used throughout this manual are as follows: CAUTION advising of potential damage to product.
  • Page 6 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST EXCESSIVE EXPOSURE TO UV RADIATION 1. Many VARI❋LITE® luminaires use a lamp that produces UV radiation. DO NOT look directly at lamp. 2. It is hazardous to operate luminaires without lens or shield. Shields, lenses, or ultraviolet screens shall be changed if they have become visibly damaged to such an extent that their effectiveness is impaired.
  • Page 7 OREWORD Sicherheitshinweise Es ist äußerst wichtig, ALLE Sicherheitsinformationen und -hinweise in diesem Handbuch und dem beiliegenden Informationsmaterial zu lesen, bevor Sie die hierin beschriebenen Produkte installieren bzw. bedienen. Halten Sie bei der Installation und dem Einsatz dieses Produkts alle Warnhinweise und Vorsichtsmaßnahmen ein.
  • Page 8 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL WARNUNG: HINWEISE ZUM SCHUTZ GEGEN ÜBERHÖHTE UV-STRAHLUNG 1. Viele VARI❋LITE®-Scheinwerfer verwenden die Lampentyp, der UV-Strahlen abgibt. SCHAUEN SIE NICHT direkt in die Lampe. 2. Es ist gefährlich, Leuchten ohne Linsen oder Blenden zu bedienen. Blenden, Linsen oder Ultraviolettschirme müssen ausgetauscht werden, sofern deren Schutzwirkung durch sichtbare Beschädigung (z.
  • Page 9 OREWORD Notes de sécurité Avant de procéder à l’installation des produits décrits dans ce guide et de les mettre en marche, il est extrêmement important de lire TOUS les renseignements et TOUTES les directives de sécurité contenues dans ce guide ainsi que toute documentation jointe. Tenir compte de tous les avertissements et suivre toutes les précautions pendant l’installation et l’utilisation de cet appareil.
  • Page 10 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL AVERTISSEMENT: DIRECTIVES POUR SE PROTÉGER CONTRE UNE EXPOSITION EXCESSIVE AUX RAYONS UV 1. Plusieurs luminaires VARI❋LITE® utilisent une lampe qui produit des rayons UV. NE PAS fixer son regard sur la lampe. 2.
  • Page 11 OREWORD Aviso sobre Seguridad Es muy importante leer TODA la información e instrucciones sobre seguridad que se indica en este manual así como en los documentos adjuntos antes de instalar y operar los productos descritos. Se debe prestar atención a todos los avisos y advertencias durante la instalación y uso de este producto. Los símbolos de seguridad usados en este manual son los siguientes: CUIDADO, indica posibles daños al producto.
  • Page 12 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL ADVERTENCIA: INSTRUCCIONES PARA PROTECCIÓN CONTINUA CONTRA LA EXPOSICIÓN EXCESIVA DE RADIACIÓN ULTRA VIOLETA 1. Muchas luminarias VARI❋LITE® usan un tipo de lámpara que produce radiación UV. NO mire directamente a la lámpara. 2.
  • Page 13 OREWORD 02. 96 63. 000 1 G 05-Oct-2007...
  • Page 14 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL xi i 05-Oct-2007 02. 96 63. 000 1 G...
  • Page 15: Table Of Contents

    ABLE OF ONTENTS Table of Contents Introduction About This Manual ...................... 1 Text Conventions ......................1 Additional Documentation................... 2 Customer Service ......................2 Chapter 1. Description Features Standard Features......................4 Model Specific Features....................4 Components Included Items......................6 Luminaire Overview ....................7 Dimmer Model Overview ....................
  • Page 16 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Chapter 3. Operation DMX Operation Channel Mapping....................... 34 Control Channel Functions ..................36 DMX Data Display ....................37 DMX Mapping Color Mixing......................38 Rotating Gobo Wheel....................39 Index/Rotation......................39 Shutter Mechanism ....................40 Luminaire Timing Timing Channel Information ..................
  • Page 17 ABLE OF ONTENTS Optical........................73 Operational......................... 74 Arc Ballast Unit (Arc Models Only)................76 Input........................76 Output ........................76 Weight and Dimensions ..................76 Returning Parts for Service 02. 96 63. 000 1 G 05-Oct-2007...
  • Page 18 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL 05-Oct-2007 02. 96 63. 000 1 G...
  • Page 19: Introduction

    NTRODUCTION BOUT ANUAL Introduction About This Manual This manual provides necessary information regarding safety, installation, operation and routine maintenance for the VARI❋LITE® VL1000™ Ellipsoidal Reflector Spotlight (ERS) luminaire. Familiarizing yourself with this information will help you to get the most out of your product. WARNING: It is important to read ALL accompanying safety and installation instructions to avoid damage to the product and potential injury to yourself or others.
  • Page 20: Additional Documentation

    ’ UMINAIRE ANUAL Additional Documentation A service manual for extended maintenance of the VL1000 ERS luminaire is available in both printed and electronic (PDF) formats: • VL1000 ERS Luminaire Service Manual (02.9663.0010) - Testing, Troubleshooting, Component Replacement and Illustrated Parts Breakdown.
  • Page 21: Chapter 1. Description

    HAPTER Description This chapter contains descriptions of luminaire features and components, along with a list of accessories which are available. • Features • Components • Accessories 02. 96 63. 000 1 G 05-Oct-2007...
  • Page 22: Features

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Features Standard Features VL1000 Ellipsoidal Reflector Spotlight (ERS) luminaires have the following standard features: • Automated zoom optics system. • Crossfading CYM color system. • Diffusion system. • Six-position rotating gobo wheel (five rotatable, indexable gobo positions and one open gobo position).
  • Page 23 ESCRIPTION EATURES VL1000 TID Luminaire (20.9663.0001.23) • 1000W Tungsten Halogen lamp source. • 115V on-board dimmer. • Beam-size iris mechanism. VL1000 TSD230 Luminaire (20.9663.0001.32) • 1000W Tungsten Halogen lamp source. • 230V on-board dimmer. • Four-blade shutter framing system. VL1000 TID230 Luminaire (20.9663.0001.33) •...
  • Page 24: Components

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Components Included Items The following illustration shows the included components for either the incandescent or arc models. Incandescent Models Neutrik PowerCon ® Unconnectorized AC Input Connector Lamp Cable VL1000 Luminaire Arc Models Neutrik PowerCon ®...
  • Page 25: Luminaire Overview

    ESCRIPTION OMPONENTS Luminaire Overview The following illustration shows the external luminaire components and controls. Base Input Panel Provides hook mounting holes and safety cable Provides DMX In and connection. Thru, and AC Power connections. Yoke Leg (Control) Contains main control Latch PCB and display PCB.
  • Page 26: Dimmer Model Overview

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Dimmer Model Overview An on-board dimmer is included with VL1000 incandescent dimmer models. The dimmer heatsink is visible on the power-side yoke leg as shown in the following illustration. On-Board Dimmer Internal lamp power dimmer, configured for either 115V or 230V operation depending on model.
  • Page 27: Arc Model Overview

    ESCRIPTION OMPONENTS Arc Model Overview An external ballast unit is included with VL1000 arc models. In this case, the lamp power input cable is already connectorized for use with this unit. The following illustration shows the external arc ballast components. Lamp Power Input Cable Supplied cable and connector used Lamp Connector...
  • Page 28: Accessories

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Accessories VL1000 ERS Replacement Items/Accessories The following optional and/or replacement items can be ordered directly from Vari-Lite. (Please order by Vari-Lite part number.) CCESSORY 21.9663.1400 Beam-Size Iris Assembly (Non-Shutter Units) 22.9620.0194 Safety Cable Assembly 25.9661.0056...
  • Page 29: Chapter 2. Installation

    HAPTER Installation This chapter contains instructions for installation of the luminaire. It includes connecting power and data, along with instructions for powering up the luminaire for the first time and addressing it within your system. • Power and Data Cabling Requirements •...
  • Page 30: Power And Data Cabling Requirements

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Power and Data Cabling Requirements AC Power The luminaire requires standard AC power distribution from 90-264 VAC, 50/60 Hz in order to power all internal electronics and motors. It is equipped with a 3-pole Neutrik® PowerCon® locking connector (with contacts for line, neutral, and premating safety grounds) for the purpose of AC input.
  • Page 31: Lamp Power

    Figure 2-2: Lamp Power Input Incandescent Models (without On-Board Dimmer) Some incandescent versions of the VL1000 ERS luminaire will require an external dimmer unit for lamp power. A lamp power input cable is provided for connecting to these units. Install a connector...
  • Page 32 Arc Models An external ballast unit is included with the arc version of the VL1000 ERS luminaire. The lamp power input cable is already connectorized for use with this unit. Note: There is no provision for lengthening the cable. The ballast must be placed within 40 inches (1m) of the luminaire.
  • Page 33: Data Cables

    NSTALLATION OWER AND ABLING EQUIREMENTS Data Cables The luminaire is equipped with two, 5-pin XLR connectors for DATA IN and DATA THRU (out) applications. DATA IN requires a 5-pin, female XLR connector and DATA THRU requires a 5-pin, male XLR connector. When purchasing or constructing data cables, it is important that not only the correct cable type be used, but also quality cable to ensure a reliable DMX512 system.
  • Page 34: Recommended Cable Types/Manufacturers

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Recommended Cable Types/Manufacturers These are only a few of the suitable cable types. Any quality EIA485, twisted pair, 120 ohm, shielded cable will also work. ∗ Type Pairs Jacket Temp (F) ZΩ...
  • Page 35: Dmx Termination Connector

    NSTALLATION OWER AND ABLING EQUIREMENTS DMX Termination Connector A male XLR DMX termination connector is required at the last luminaire (or "far end of the line") to prevent signal reflections. Signal reflections may cancel out the signal at certain line lengths, resulting in errors. The terminator is also necessary for software downloads and running tests on multiple luminaires.
  • Page 36: Installation Procedures

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Installation Procedures Installing Lamp (Incandescent Models) In the event the lamp was packed separately during shipment, it will be necessary to install before use. WARNING: Ensure that power is removed from luminaire when installing lamp. CAUTION: Wear cotton gloves or other covering while installing lamp.
  • Page 37 NSTALLATION NSTALLATION ROCEDURES Step 3. At backcap, flip two bail clamps outward (Figure 2-5). Step 4. Flip two base clamps outward away from socket. Step 5. Grip lamp by base and firmly install in socket. Step 6. Close base and bail clamps, locking into place. Do not touch lamp CAUTION: with bare fingers.
  • Page 38: Installing Lamp (Arc Models)

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Installing Lamp (Arc Models) In the event the lamp was packed separately during shipment, it will be necessary to install before use. WARNING: Ensure that power is removed from luminaire when installing lamp. CAUTION: Wear cotton gloves or other covering while installing lamp.
  • Page 39 NSTALLATION NSTALLATION ROCEDURES Step 3. Grip lamp by base and firmly install in socket. Do not touch lamp CAUTION: with bare fingers. Socket Lamp Install lamp, firmly pressing into place. Figure 2-7: Installing Arc Lamp in Socket Step 4. Re-install backcap, ensuring that alignment studs and holes are aligned (Figure 2-6).
  • Page 40: Accessory Frame Holder

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Accessory Frame Holder An accessory frame holder is provided for the addition of a top hat or gel frame with silks, frosts or color correction if required. The frame holder is designed to fit a standard 8-inch gel frame or top hat. To remove and replace frame or top hat: Step 1.
  • Page 41: Hanging The Luminaire

    NSTALLATION NSTALLATION ROCEDURES Hanging the Luminaire The luminaire can be hung horizontally or vertically from any structure designed to work with the type of load created by this moving luminaire. The pan tube base provides two mounting holes for attaching truss hooks or other mounting hardware as required.
  • Page 42 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL To hang luminaire in truss: Step 1. Lift luminaire into mounting position. Step 2. Secure in place with truss hooks. Ensure truss hook hardware that locks hook in place (e.g. wing bolt) is properly tightened and that luminaire is fully supported.
  • Page 43: Hanging The Ballast (Arc Models Only)

    NSTALLATION NSTALLATION ROCEDURES Hanging the Ballast (Arc Models Only) The external ballast unit included with arc models will need to be installed near the luminaire. In order for the lamp cable to be connected, the ballast must be placed within 40 inches (1m). The top panel provides one mounting hole for attaching a truss hook or other mounting hardware as required.
  • Page 44 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL To hang arc ballast in truss: Step 1. Lift ballast into mounting position. Step 2. Secure in place with truss hook. Ensure truss hook hardware that locks hook in place (e.g. wing bolt) is properly tightened and that ballast is fully supported.
  • Page 45: Connecting Data And Power

    NSTALLATION NSTALLATION ROCEDURES Connecting Data and Power A maximum of 32 luminaires may be connected in any one DMX data link. Note: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require fewer luminaires on a single data link path. Consult your console documentation for more information.
  • Page 46: Powering Up

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Powering Up Power-Up and Configuration Overview First Power-Up When powering up a VL1000 luminaire for the first time, the lamp type and shutter settings must be configured. This procedure will usually happen prior to delivery. However, in the event that it has not been done or if the Main Controller Board has been replaced, it will be necessary.
  • Page 47: Standard Power Up Procedure

    NSTALLATION OWERING Standard Power Up Procedure Use this procedure when powering up a luminaire that has already been configured. (Refer to “Power- Up and Configuration Overview” on page 28.) Note: Refer to Chapter 4: Menu System for detailed instructions on menu functions. CAUTION: Before applying power, be sure the luminaire is hung or positioned so that the head and yoke can move freely without restriction.
  • Page 48: Power Up And Configuration Procedure

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Power Up and Configuration Procedure Use this procedure when powering up a luminaire that has not been previously configured. (Refer to “Power-Up and Configuration Overview” on page 28.) Note: Refer to Chapter 4: Menu System for detailed instructions on menu functions.
  • Page 49: Align Lamp For Maximum Beam Irradiance

    NSTALLATION OWERING Align Lamp For Maximum Beam Irradiance After a new lamp is installed in either the incandescent or arc version of the luminaire, it will be necessary to align the lamp to optimize the beam. WARNING: Backcap and adjustment screws will be HOT during lamp operation. Wear gloves and/or use tools to prevent burns.
  • Page 50: Addressing

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Addressing Program Starting Address The DMX starting address is entered using the Menu Display. This address will be retained even if the power is removed. Note: Refer to Chapter 4: Menu System for detailed instructions on menu functions.
  • Page 51: Chapter 3. Operation

    HAPTER Operation This chapter contains instructions for operating the luminaire using DMX control and for updating the internal software. • DMX Operation • DMX Mapping • Luminaire Timing • Updating Software 02. 96 63. 000 1 G 05-Oct-2007...
  • Page 52: Dmx Operation

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL DMX Operation Channel Mapping These tables assume a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in sequence. (There is only one DMX mode for this luminaire, which is Enhanced 16-bit Mode.) Table 3-1: Enhanced 16-Bit Mode - Models VL1000 TI/AI DMX Channel...
  • Page 53 : DMX O PERATION PERATION Table 3-2: Enhanced 16-Bit Mode - Models VL1000 TS/AS DMX Channel Parameter Range Dimmer * 0-255 Hi Byte Pan 0-65535 Lo Byte Pan 0-65535 Hi Byte Tilt 0-65535 Lo Byte Tilt 0-65535 Edge 0-255 Zoom 0 (small) - 255 (big) Diffusion 0 (open) - 255 (diffused)
  • Page 54: Control Channel Functions

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Control Channel Functions Control channel functions allow special actions such as reset, lamp on/off and partial recalibration. These must be executed with zero time transition or with timing disabled. Discrete values must be used;...
  • Page 55: Dmx Data Display

    : DMX O PERATION PERATION DMX Data Display The DMX data display shows the data received for the given luminaire and does not show the entire stream of 512 bytes. It shows only the number of channels used for the given luminaire model in 16- bit enhanced mode.
  • Page 56: Dmx Mapping

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL DMX Mapping Color Mixing The color mixing mechanism is a CYM subtractive color mixing system made up of a graduated color system for cyan, yellow, and magenta. Table 3-4: DMX Map For Cyan % Value DMX Value Action...
  • Page 57: Rotating Gobo Wheel

    : DMX M PERATION APPING Rotating Gobo Wheel The function operates in two modes: INDEX Mode and ROTATE Mode. The DMX values corresponding to these modes are as follows: • DMX values 0-127 will select each gobo in Indexing mode. •...
  • Page 58: Shutter Mechanism

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Shutter Mechanism For units with a shutter mechanism, the shutter is comprised of four frame blades that move independently or in unison. The entire assembly operates in a smooth, time-continuous motion using stepper motors (two per frame blade and one to rotate the entire shutter mechanism).
  • Page 59: Luminaire Timing

    PERATION UMINAIRE IMING Luminaire Timing Timing Channel Information Timing channel control improves the timed moves of certain groups of parameters. We provide three timing channels, one for Focus (Pan and Tilt), one for color parameters and one for beam parameters. Timing channels support time values of up to six minutes.
  • Page 60 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Note: Avoid changing timing channel values in a fading cue. This can cause unexpected behavior in the luminaire as the timing channel value is updated over time. Timing channel values and the final destination of the parameters affected by the timing channel should always be sent in a zero count.
  • Page 61 PERATION UMINAIRE IMING Table 3-11: VL1000 Timing Channels Map % Value = Seconds 10.2 10.4 10.6 02. 96 63. 000 1 G 05-Oct-2007...
  • Page 62 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Table 3-11: VL1000 Timing Channels Map % Value = Seconds 05-Oct-2007 02. 96 63. 000 1 G...
  • Page 63 PERATION UMINAIRE IMING Table 3-11: VL1000 Timing Channels Map % Value = Seconds 02. 96 63. 000 1 G 05-Oct-2007...
  • Page 64 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Table 3-11: VL1000 Timing Channels Map % Value = Seconds 05-Oct-2007 02. 96 63. 000 1 G...
  • Page 65 PERATION UMINAIRE IMING Table 3-11: VL1000 Timing Channels Map % Value = Seconds 02. 96 63. 000 1 G 05-Oct-2007...
  • Page 66 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Table 3-11: VL1000 Timing Channels Map % Value = Seconds Follows Cue Data 05-Oct-2007 02. 96 63. 000 1 G...
  • Page 67: Updating Software

    PERATION PDATING OFTWARE Updating Software Reprogramming Luminaires You can upgrade Vari-Lite luminaire operating software using either of the following methods: 1. Serial-port Download—for desktop computers and laptops equipped with serial ports 2. USB Download—for desktop computers and newer laptops equipped with USB 2.0 ports 1.
  • Page 68: Reprogramming Procedure

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Reprogramming Procedure Note: When they are data linked together, up to 32 luminaires can be programmed at the same time. Refer to “Connecting Data and Power” on page 15. (Programming more than 32 luminaires requires programming in batches of 32 or less.) To update luminaire software: Step 1.
  • Page 69 PERATION PDATING OFTWARE Step 9. Click Close to exit. Note: The History section of the window shows what specific types of luminaire software have been downloaded since the beginning of the session (window will reset once the program is closed and re- opened).
  • Page 70: Usb Download

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL 2. USB Download To download files with a PC equipped with a Universal Serial Bus (USB) port, you need the VARI❋LITE USB Luminaire Programming Kit (28.8500.0054). Kit Components The VARI❋LITE USB Luminaire Programming Kit (28.8500.0054) includes: •...
  • Page 71 PERATION PDATING OFTWARE A termination connector is used in this process. Refer to page 10 for more information regarding the construction of this connector. Master luminaire containing Luminaire 1 Luminaire 2 software version to download requiring update requiring update AC PWR AC PWR AC PWR DATA IN...
  • Page 72 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Notes 05-Oct-2007 02. 96 63. 000 1 G...
  • Page 73: Chapter 4. Menu System

    HAPTER Menu System This chapter contains instructions for operating the luminaire using the Menu Display feature. • Menu Operation • Menu Functions • Self Tests 02. 96 63. 000 1 G 05-Oct-2007...
  • Page 74: Menu Operation

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Menu Operation What Is the Menu System? The menu system is a programmable set of commands used to configure, address, operate, and test the luminaire. The menu system is controlled at the Menu Display available at the yoke leg.
  • Page 75: Menu Default State

    YSTEM PERATION Menu Default State The menu display’s default state during normal operation is to display the address. After 10 seconds of inactivity at the display, it will change to this default state. After 5 minutes of inactivity, the menu display will switch to its off state. Menu Shortcuts A few button combinations are provided as shortcuts for frequently used menu functions.
  • Page 76: Menu Functions

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Menu Functions Menu System Overview The following is a graphic representation of the entire menu system. Manual value Address value Tilt value Dimmer* value Blue value Setup LampType Amber value Incand Magenta value...
  • Page 77: Menu System Function Chart

    YSTEM UNCTIONS Menu System Function Chart 1st Level 2nd Level 3rd Level 4th Level 5thLevel Address DMX DMX Address XXX Address value Setup LampType Incand Shutter? Config LAMP Lamp Options Power Lamp Power ON (default) System (Arc Only) Configuration P UP Lamp Power-up State Lamp OFF Lamp Cal ON Lamp On After Calibration...
  • Page 78 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL 1st Level 2nd Level 3rd Level 4th Level 5thLevel Fixture Status Status/Error Display Scrolls error messages or displays OK Re-Cal Recalibrate Model Luminaire Model Type VL1000XX Model Type Lum Id Luminaire ID XXXXXXXX Luminaire ID Number Version Version...
  • Page 79 YSTEM UNCTIONS 1st Level 2nd Level 3rd Level 4th Level 5thLevel Test ALL Test All Motors RUN TEST Run-Test in Progress Press [Menu] to System Test stop tests Pan/Tilt RUN TEST Run-Test in Progress Dimmer (Arc Only) RUN TEST Run-Test in Progress Blue RUN TEST Run-Test in Progress Amber...
  • Page 80: Menu Function Definitions

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Menu Function Definitions For easy reference, each possible menu item is listed alphabetically in the first column by its display abbreviation. The second column follows with a definition of the abbreviation and then a third column provides an explanation of its purpose and function.
  • Page 81 YSTEM UNCTIONS Display Definition Purpose Lamp Lamp Accesses lamp power up options and information (Config). Lamp OFF Lamp is Off Configures arc luminaire so that lamp will not strike upon power up. Lamp ON Lamp is On Configures arc luminaire so that lamp will strike upon power up. LampHour Lamp Hours Displays total number of lamp operating hours.
  • Page 82: Self Tests

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Self Tests Running Parameter Tests The luminaire is capable of running self tests by using the TEST menu functions. Note: If a DMX data stream is present on the luminaire’s DMX input connector, Self Test and Manual control is overwritten by the DMX command protocol and neither (Self Test and Manual) will operate.
  • Page 83 YSTEM ESTS Movement Disable The Movement option allows pan and tilt to be disabled so that the luminaire can be placed in any position for testing without movement occurring. In order to regain full control of the luminaire, Movement will need to be enabled after testing. Note: When using the Movement option, pan and tilt will be disabled for all the luminaires that are linked.
  • Page 84 ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Notes 05-Oct-2007 02. 96 63. 000 1 G...
  • Page 85: Appendix A. Troubleshooting And Maintenance

    PPENDIX Troubleshooting and Maintenance This appendix provides instructions for troubleshooting and performing routine maintenance which may be necessary during the life of the luminaire. • Troubleshooting • Routine Maintenance WARNING: All maintenance procedures are to be performed with power removed from the luminaire.
  • Page 86: Troubleshooting

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Troubleshooting Error Messages If a problem occurs during luminaire calibration, at the end of the calibration sequence the Menu Display will cycle through any applicable error message(s) until the end of the list is reached. To review the error messages again, it will be necessary to access them using the Status function.
  • Page 87: Troubleshooting Guide

    ROUBLESHOOTING AND AINTENANCE Troubleshooting Guide If a problem is suspected, first try recalibrating the luminaire to prompt an error message. The chart below provides possible causes and remedies for various error messages and/or symptoms. CAUTION: Some troubleshooting is included for reference only. Performing remedies marked by gray areas will void product warranty.
  • Page 88: Routine Maintenance

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Routine Maintenance Cleaning Optical Lenses and Gobos WARNING: Remove power from luminaire before performing maintenance. The front lens and gobos may require cleaning after extended use. A common glass cleaner can be used along with a soft, lint-free cloth to clean these components.
  • Page 89 ROUBLESHOOTING AND AINTENANCE Step 7. Re-install front cover. Inside Edge - orient toward center of wheel Rotate until open end of carrier is up CAUTION: Gear Closed End Open End Gobo MUST be oriented with the mirrored side towards the luminaire’s lamp. If not oriented properly, gobo will break.
  • Page 90: Lamp Replacement

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Lamp Replacement For lamp replacement procedure, refer to “Installation Procedures” on page 05-Oct-2007 02. 96 63. 000 1 G...
  • Page 91: Appendix B. Technical Specifications

    PPENDIX Technical Specifications Mechanical Zoom Optics Continuously variable field angle in imaging range from 19° to 36°, super zoom of field to 70° programmable over a timed range of 2 seconds to 20 minutes. Color Mixing Fully crossfading CYM color system. Diffusion Field or gobo can be continuously and smoothly diffused to wash.
  • Page 92: Operational

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Operational Power Requirements Depending on voltage, 1 to 2 Amps are supplied to Incandescent models through standard AC distribution while 3 to 9 Amps are supplied to Arc luminaires and ballast. Operational Temperature -20°...
  • Page 93 ROUBLESHOOTING AND AINTENANCE Photometric VL1000 ERS luminaire - 1000W Tungsten Halogen (All data taken with a seasoned light source at 20 hours of life.) FIELD ANGLE FIELD DIAMETER BEAM ANGLE BEAM DIAMETER CANDELA (degrees) (degrees) (cd) 19.0 .335 13.0 0.228 218,000 26.0...
  • Page 94: Arc Ballast Unit (Arc Models Only)

    ❋ VARI LITE® - VL1000™ ERS L ’ UMINAIRE ANUAL Arc Ballast Unit (Arc Models Only) Input Voltage Range 90V to 275V, auto-ranging. Frequency 50 Hz or 60 Hz Current Range 4.54" 2.7 A to 9.0 A* (11.5 cm) Power Factor +/- .97 Output 13.43"...
  • Page 95 Returning Parts for Service Obtaining RMA Number and Returning Parts 1. Contact Service Center. 2. Request Return Material Authorization (RMA) number. 3. Do not remove glass color discs from luminaire subassemblies. 4. Package all parts being shipped. Please take great care in packing your items. Wrap all subassemblies and loose parts in bubble wrap or specialty packing material (if required) before shipping.