System Design; Electrical Wiring For Details; Tools Required For Installation (Not Supplied); Accessories Supplied With Outdoor Unit - Sanyo SPW-CR365GXH56 Technical Data Manual

Mini eco-i system
Hide thumbs Also See for SPW-CR365GXH56:
Table of Contents

Advertisement

2. System Design

2-1. Tools Required for Installation (not supplied)

1.
Standard screwdriver
2.
Phillips head screwdriver
3.
Knife or wire stripper
4.
Tape measure
5.
Carpenter's level
6.
Sabre saw or key hole saw
7.
Hacksaw
8.
Core bits
9.
Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for deburring)

2-2. Accessories Supplied with Outdoor Unit

Table 2-1 Outdoor Unit
Part name
Tube Discharge
Assy
Instruction manual
2-4. Additional Materials Required for Installation
1. Refrigeration (armored) tape
2. Insulated staples or clamps for connecting wire
(See your local codes.)
3. Putty
4. Refrigeration tubing lubricant
5. Clamps or saddles to secure refrigerant tubing
6. Scale for weighing
Quantity
Figure
365 Model
485 Model
(4 hp)
0
paper
1
Design of Mini ECO-i SYSTEM
2-3. Type of Copper Tube and Insulation Material
If you wish to purchase these materials separately
from a local source, you will need:
1. Deoxidized annealed copper tube for refrigerant
tubing.
2. Foamed polyethylene insulation for copper tubes as
required to precise length of tubing. Wall thickness
of the insulation should be not less than 8 mm.
3. Use insulated copper wire for field wiring. Wire
size varies with the total length of wiring. Refer to

3. ELECTRICAL WIRING for details.

CAUTION
605 Model
(5 hp)
(6 hp)
0
1
1
1
hp = horsepower
2 - 13
Check local electrical codes
and regulations before
obtaining wire. Also, check
any specified instructions
or limitations.
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents