Sanyo SPW-CR365GXH56 Technical Data Manual page 158

Mini eco-i system
Hide thumbs Also See for SPW-CR365GXH56:
Table of Contents

Advertisement

1. Outdoor Unit
Outdoor unit (E)
MODEL No.
Power source
Controller P.C.B. Ass'y
Control circuit fuse
Compressor
Type
Model ... Code No.
Motor rated output
Compressor oil (ETHER FV68S)
Coil resistance
(Ambient temperature 25°C)
Safety devices
Thermal protector ON / OFF
Microprocessor safety devices
Crank case heater
High pressure switch
Set pressure ON / OFF
4
Fan (Number ... diameter (mm))
Fan motor
Model ... Nominal output
No. of pole ... r.p.m.
Safety device
Microprocessor safety devices
Heat exchanger
Coil
Rows...fin pitch
Face area
Mini ECO-i SYSTEM Unit Specifications
380 - 400 - 415 V / 3N / 50 / 60 Hz
C-9RVN273H0R ... 808675805
kW
cc
V - U: 0.552, U - W: 0.552
Compressor current detection circuit
Compressor discharge gas temperature control
V, W
MPa
Propeller (1 ... ø460) × 2
W
DAJ12 – 95A61A / B – C ... 90W
Aluminum plate fin / Copper tube
mm
m
2
4 - 16
SPW-CR485GXH8B
CR-CR605GXH8
250V, 6.3A
INV (Inverter)
Rotary (Hermetic)
3.3
1,900
W - V: 0.552
240, 25
8 ... 250 – 800
Yes
3 ... 1.4
3.25

Hide quick links: