ECO GOLD
7.5

Other settings

7.5.1

Defining temperature limits

With this function it is possible to define a minimum and maximum temperature within which the controller
operates. If, for example, you are using water as the heat transfer liquid, +95 °C would be practicable as
the maximum temperature and +5 °C the minimum temperature.
Limits
T il
T il
‫ סּ‬OK
ESC
T il
Lower limit
Max:202.0
Min:-30.0
-30,0
‫ סּ‬OK
ESC
28.04.10/ YACE0088
Access to the main menu level is obtained by pressing
-30.0°C
202.0°C
The adjacent menu window appears by selecting and
confirming
Select the lower (Til) or upper (Tih) limit with
and confirm it with
flashes below the value to be changed. The permissible
Standby
adjustment range is indicated with Min and Max.
Change the value with
By pressing
vidually and change them with
By pressing
selected.
You confirm the set value by pressing
By pressing
Standby
level without the set-point being changed.
Putting the device into operation
.
Setup
Limits.
. In the entry window the cursor
or
or
you can also select numbers indi-
(+/-) the arithmetic sign "+" or "-" can be
(ESC) you are returned to the menu
or
.
or
.
.
39