Feed To All Bins; Sensor Tests; Finisher Tests; Staple Test - Lexmark C93x Service Manual

Color laser printer
Table of Contents

Advertisement

Press Stop
While this test runs, [Selected Output Bin] Feeding...appears on the LCD. During Single tests, no
buttons are active. However, during Continuous tests, you can press Stop

Feed To All Bins

This test can be used to verify that the printer can feed media to the standard bin or any installed output options.
No information will be printed on the test pages, as the printhead is not engaged during the feed test. The media
feeds from the default paper source.
To run the Feed To All Bins Test:
1. Select OUTPUT BIN TESTS from the Diagnostics Menu.
2. Select Feed To All Bins.
The printer feeds media from the default source to each installed bin. After the test is selected, the printer feeds
a separate piece of media to the standard bin first, then it feeds a separate piece of media to each output bin
installed. While this test runs, All Bin Test Feeding... appears on the LCD.
The test is continuous until Stop
on the LCD and feeds any remaining media in the paper path to the appropriate output destination.
Sensor Test (output bin)
This test is used to verify that a specific output bin's sensors are working correctly.
To run the Output Bin Sensor Test
1. Select OUTPUT BIN TESTS from the Diagnostics Menu.
2. Select Sensor Test.
3. Select Standard Bin.
4. Select Standard bin full.
1. Select OUTPUT BIN TESTS from the Diagnostics Menu.
2. Select Sensor Test.
3. Select Finisher Standard Bin.
4. Select Finisher upper media bin full.
1. Select OUTPUT BIN TESTS from the Diagnostics Menu.
2. Select Sensor Test.
3. Select Finisher Bin 1.
4. Select Stacker bin level 1, Stacker bin level 2, or Booklet bin media present.
XXXXXXXXXX Testing...appears on the LCD and XXXXXXXXXX: [Open] or [Closed].
You can manually toggle the sensor between its two values (Open or Closed). The LCD displays Open when
the sensor is open, and Closed when the sensor is closed. If the wrong message is displayed, then the sensor
must be malfunctioning.
Press Stop

FINISHER TESTS

Staple Test

This test is used to verify the functioning of the finisher's staple mechanism.
to return to the [Selected Output Bin].
is pressed. If a test is canceled, All Bin Test Canceled... appears
to exit the test.
5057-XXX
to cancel the test.
Diagnostic aids