5.4.4
CHANGING FROM ROUND JET NOZZLE TO FLAT JET NOZZLE
1. Switch off control unit.
2. Relieve spray gun and unit pressure.
3. Unscrew the nozzle nut EAR (B).
4. Remove round nozzle body (C) with
nozzle insert Supra (A).
5. Place fl at jet nozzle (E) into air cap (F).
Place both of them onto the valve seat.
6. Screw nozzle nut EAF (H) on the gun
body (K) Adjust desired jet position by
means of air cap horn (L). Tighten air
cap nut (F) by hand.
5.4.5
FITTING OR CHANGING FLAT JET NOZZLE
Perform steps 1 to 6 of paragraph 5.4.3
7. Unscrew nozzle nut (H) by hand.
8. Remove air cap (F) and fl at jet nozzle (E)
Assembly:
According to steps 5 and 6 of paragraph 5.4.4
PART NO. DOC388891