5.3
START-UP
5.3.1
GENERAL RULES FOR MAKING ADJUSTMENTS TO THE SPRAY GUN
➞ See safety regulations in chapter 2.
High voltage field!
Danger to life from malfunctioning heart pacemakers
Ensure that persons with heart pacemakers:
SIHI_0049_GB
Unintentional putting into operation!
Risk of injury
Before all work on the unit, in the event of work interruptions and
functional faults:
SIHI_0065_GB
5.3.2
PREPARATION
•
Secure the spray gun. Turn tension cap clockwise until stop (viewed from back of gun).
•
Connect material hose to pump.
•
Connect air hose to oil free, dry air supply approx. 0.25 MPa; 2.5 bar; 36 psi with
regulator.
•
Connect electric cable of the spray gun to the control unit.
•
Visually check the permissible pressures for all the unit components.
•
Make sure that the spraying unit and all other conductive parts within the work area are
earthed.
•
Set material pressure and use a suitable medium (solvent or water) to check that
connections do not leak.
•
Relieve unit pressure and secure the spray gun.
PART NO. DOC388891
Do not work with the electrostatic spray gun.
Remain outside the area of the electrostatic spray gun/work -
piece.
WARNING
Switch off the energy/compressed air supply.
Relieve the pressure from the spray gun and unit.
Secure the spray gun against actuation.
By functional faults: Identify and correct the problem, proceed
as described in chap„Trouble shooting".
DANGER
GM 2800EA