3.3.2.2
Buffered AI Trigger and CLK Source Connections
The PCI-1706U introduces a double-clock system, with SCAN clock and CONV
clock, to generate efficient A/D conversion clocks at dedicated timing. A/D conver-
sion clocks come from internal clock sources or external signals on connector. The
CLK has several sources.
Internal A/D clock derived from 32-bit divider
External A/D clock from terminal board
With PCI-1706U, user can define the type of trigger source as rising-edge or falling-
edge. The Trigger has several sources.
External digital (TTL) trigger from terminal board
Soft trigger
Analog threshold trigger
Figure 3.5 Trigger Source and CLK Source Connection
Figure 3.4 Differential input channel connection -

floating signal source