Selecting Factory Or User Coefficients; Enabling Pixel Coefficients - Dalsa 4M30 User Manual

4 megapixel 30/60 fps area scan cameras
Hide thumbs Also See for 4M30:
Table of Contents

Advertisement

Falcon 4M Camera Manual

3.7.1 Selecting Factory or User Coefficients

Purpose:
Syntax:
Syntax Elements:
Notes:
Example:

3.7.2 Enabling Pixel Coefficients

Purpose:
Syntax:
Syntax Elements:
Notes:
Example:
DALSA
Selects the coefficient set to use. The camera ships with a factory
calibrated set of FPN and PRNU coefficients. The factory coefficients
cannot be erased or modified.
csn i
i
Coefficient set number to use.
0-7 = Factory calibrated sets of FPN and PRNU coefficients.
These coefficients cannot be erased or modified.
8-15 = User calibrated sets of FPN and PRNU coefficients.
These coefficients can be deleted or modified.
The camera ships with factory calibrated FPN and PRNU
coefficients saved to sets as follows:
CSN
EFD
0, 3, 8, 11
1
1, 4, 9, 12
0
2, 5, 10, 13
2
6, 14
All coefficients = 0
7, 15
FPN/PRNU Test Pattern
When you first boot up the camera, the camera operates using
set 8 (csn 8) enabled.
csn 0
The camera ships with the FPN and PRNU coefficients enabled, but
you can enable and disable FPN and PRNU coefficients whenever
necessary.
epc i i
i
FPN coefficients.
0 = FPN coefficients disabled
1 = FPN coefficients enabled
i
PRNU coefficients.
0 = PRNU coefficients disabled
1 = PRNU coefficients enabled
The coefficient set that you are enabling or disabling is
determined by the csn value. Refer to the previous section for
an explanation of the csn command.
epc 0 1
45
03-032-20044-01

Advertisement

Table of Contents
loading

Table of Contents