Saving And Restoring Settings - Dalsa 4M30 User Manual

4 megapixel 30/60 fps area scan cameras
Hide thumbs Also See for 4M30:
Table of Contents

Advertisement

Falcon 4M Camera Manual
PT-21-04M30

3.2 Saving and Restoring Settings

Figure 9: Saving and Restoring Overview
Factory Settings
You can restore the original factory settings at any time using the command rfs.
Note: This command does not restore flat field coefficients. Refer to the lpc command.
User Settings
You can save or restore your user settings to non-volatile memory using the following
commands.
DALSA
9995 µs exposure time
Camera Link mode 16 (Medium configuration, 4 taps. 10 bits)
80 MHz pixel rate (320 MHz total throughput)
Full window (2352 x 1728)
Snapshot mode 1 enabled (EFD 1)
Flat field coefficients enabled (calibrated in exposure mode 2, 29 fps, and
exposure time of 2 ms [non-concurrent readout and integration], snapshot mode
1, number of fast frame dumps = 1)
Exposure mode 2
30 fps
14992 µs exposure time
Camera Link mode 3 (Medium configuration, 2 taps. 10 bits)
80 MHz pixel rate (160 total throughput)
Full window (2352 x 1728)
Snapshot mode 1 (EFD 1)
rus
Factory
Settings
rfs
Current
Session
User
Settings
wus
23