ACCESSING THE PRESSURE TRANSDUCER TUBING,
RECIRCULATION TUBE, AND DRAIN PUMP HARNESS
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
The following procedure allows you to access
the following components for service by re-
moving the rear panel:
Drain Pump Harness
Pressure Transducer Tubing
Recirculation Tube
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Disconnect the hot and cold water hoses
from the rear of the washer, and remove
the end of the drain hose from the stand-
pipe or laundry tub.
4.
Remove the eight screws from the rear
panel and remove the panel (see the top
right photo).
Screw (1 of 8)
Pressure Transducer
Tubing Retainer Screw
Pressure Transducer
Tubing
4-18
Rear Panel
Recirculation Tube
Drain Pump Harness
Retainer Screw