Monitoring and Controlling
• Projector input port name: RS-232C
<At the projector>
<At the projector>
Signal Name
Function
GND
Signal wire ground
TD
Transmit data
RD
Receive data
Communications Protocol
• Default baud rate setting: 9600 bps
• Data length: 8 bit
• Parity: None
• Stop-bit: 1 bit
• Flow control: None
<At the computer>
(PC serial cable)
<At the computer>

About PJLink

PJLink Class1 was established by the JBMIA (Japan Business Machine and
Information System Industries Association) as a standard protocol for
controlling network-compatible projector's as part of their efforts to
standardize projector control protocols.
The projector complies with the PJLink Class1 standard established by the
JBMIA.
You need to make network settings before you can use PJLink. See the
following for more information on network settings.
"Network Menu"
s
It complies with all commands except for the following commands defined
by PJLink Class1, and agreement was confirmed by the PJLink standard
adaptability verification.
URL:http://pjlink.jbmia.or.jp/english/
• Non-compatible commands
Mute settings
• Input names defined by PJLink and corresponding projector sources
Source
Computer1
Computer2
Video
S-Video
HDMI1/MHL
HDMI2
http://www.pureglare.com.au
p.136
Function
PJLink Command
Image muting set
AVMT 11
Audio muting set
AVMT 21
PJLink Command
INPT 11
INPT 12
INPT 21
INPT 22
INPT 32
INPT 33
119