About Pjlink - Epson EB-L25000unl User Manual

Table of Contents

Advertisement

Monitoring and Controlling
• Projector input port name: RS-232C
<At the projector>
<At the projector>
Signal Name
Function
Signal wire ground
GND
Transmit data
TD
RD
Receive data
Communications protocol
• Default baud rate setting: 9600 bps
• Data length: 8 bit
• Parity: None
• Stop-bit: 1 bit
• Flow control: None
<At the computer>
(PC serial cable)
<At the computer>

About PJLink

PJLink Class1 was established by the JBMIA (Japan Business Machine and
Information System Industries Association) as a standard protocol for
controlling network-compatible projector's as part of their efforts to
standardize projector control protocols.
The projector complies with the PJLink Class1 standard established by the
JBMIA.
You need to make network settings before you can use PJLink. See the
following for more information on network settings.
"Network Menu"
p.129
s
It complies with all commands except for the following commands defined
by PJLink Class1, and agreement was confirmed by the PJLink standard
adaptability verification.
URL:
http://pjlink.jbmia.or.jp/english/
• Non-compatible commands
Function
Mute settings
Image muting set
Audio muting set
• Input names defined by PJLink and corresponding projector sources
Source
Computer
BNC
DVI-D
HDMI
SDI
LAN
195
PJLink Command
AVMT 11
AVMT 21
PJLink Command
INPT 11
INPT 13
INPT 31
INPT 32
INPT 34
INPT 52