E-Mu Ultraproteus Operation Manual page 281

Table of Contents

Advertisement

MIDI SPECIFICATION
260
Tuning Table Request
F0
18
0C
dd
04
bb
F7
Tuning Table Data
F0
18
0C
dd
05
bb
ll
mm
...
F7
Program Map Request
F0
18
0C
dd
06
bb
F7
UltraProteus Operation Manual
SysEx Status Byte
E-mu Mfg. ID
UltraProteus Product ID
Device ID 0-15
Command ID
Table Number, 0 - MAX TUNETABLE
End of SysEx Status
SysEx Status Byte
E-mu Mfg. ID
UltraProteus Product ID
Device ID 0-15
Command ID
Table Number (only 1 table in UltraProteus)
ls byte of Tune Value
ms byte of Tune Value
128 total entries
End of SysEx Status
SysEx Status Byte
E-mu Mfg. ID
UltraProteus Product ID
Device ID 0-15
Command ID
Map Number, 0-3
End of SysEx Status