Offset
Name
...
344
FX B Type
345
FX B Parm Vals
...
355
FX A Amt
356
FX B Amt
357
B->A Amt
358
FX A Bus
359
FX B Bus
cs
F7
End of SysEx Status
Parameter Request
Request a parameter value. An unknown parameter number will respond with a
value of zero. Individual parameter editing uses a unique parm number for each
editable parm. See PARAMETER NUMBERS chart for a listing of the param-
eters.
F0
SysEx Status Byte
18
E-mu Mfg. ID
0C
UltraProteus Product ID
dd
Device ID 0-15
02
Command ID
pl
Parm Number ls byte
pm
Parm Number ms byte
F7
End of SysEx Status
Parameter Data
The format of a parameter value request response is as follows. This is the
format used to edit an individual parameter.
F0
SysEx Status Byte
18
E-mu Mfg. ID
0C
UltraProteus Product ID
dd
Device ID 0-15
03
Command ID
pl
Parm Number ls byte
pm
Parm Number ms byte
vl
Parm Value ls byte
vm
Parm Value ms byte
F7
End of SysEx Status
Range
10 parm values
See EFFECTS TYPES chart
See EFFECTS TYPES chart
10 parm values
0-100%
0-100%
0-100%, 101 = B->A Only
0-2, Main, Sub1, Sub2
0-2, Main, Sub1, Sub2